Operating Indicators

Operation

Operating Indicators

Indicators at the Output End of the unit show the unit’s power status and alarms for conditions that could cause it to shut down.

Output Watts

Power on – The Voltage Input and Power Output indicators automatically toggle between input and output values at three-second intervals. The three LEDs indicate the mode the meter is in and the three digits indicate the voltage or power value.

Over Current

Current Overload Protection –

 

If the inverter is overloaded,

 

it will shut down to protect itself.

 

The meter will flash as shown to

 

indicate Overload Protect.

 

To restore normal operation,

 

disconnect the excessive load

 

and turn the unit Off and On

 

again using the Power Button.

Short Circuit

Short Circuit Protection – If the

 

AC output of the inverter is short-

 

circuited for one second or more,

 

it will shut down to protect itself.

 

The meter will flash as shown to

 

indicate Short Circuit Protect and

 

an alarm will sound.

 

To restore normal operation,

 

disconnect the short circuit and

 

turn the unit Off and On again

 

using the Power Button.

Operating Indicators

Operation

Low Voltage Low Voltage Protection – If the

DC input voltage drops below the alarm threshold of 10.5V the meter will flash as shown to indicate Low Voltage Protection, but the unit will continue to operate. If the input voltage drops to 10.0V or less, the inverter will shut down to protect itself, the meter will continue to flash as shown, and an alarm will sound.

 

To restore normal operation, return

 

the DC input voltage to at least

 

12V. The inverter will automatically

 

return to normal operation.

High Voltage

High Voltage Protection – If the

 

DC input voltage rises above 15.0V,

 

the inverter will shut down to protect

 

itself, the meter will flash as shown

 

to indicate Over Voltage Protection,

 

and an alarm will sound.

 

To restore normal operation, return

 

the DC input voltage to less than

 

15V. The inverter will automatically

 

return to normal operation.

 

 

 

 