Trade/Road Inverter Manual 9/15/97 10:16 AM Page 10
HARD-WIRED OUTPUT
If it is desired to permanently connect the inverterÕs output to a string of outlets or to a load, the remote connector should be used. The three
(4)Black: hot; and (5) Green: ground or chassis. Any
CAUTION: When making a permanent installation, make sure these same lines being fed by the inverter will never be fed by shore power, a generator, another inverter or any other source of AC; once again, that would cause damage and void the warranty. If you wish to use another source of AC on the same lines, it is necessary to disconnect the inverter first. To do this automatically, install a DPDT
7
OPERATION
Using your inverter is quite simple. Just turn the switch ON, and observe that the AC light comes on, indicating there is
115 volt AC power at the output. Any appliance connected to the inverter will operate, if it is within the inverterÕs power capability. Should you wish to connect more than one appliance to the inverter, a
Please note that the fan will run only when the inverter is loaded beyond 120 watts.
When operated at full load for extended periods it is normal for the inverter to be HOT to the touch.
The output is factory
Low Battery
If the voltage at the input terminals of the inverter drops below 10.3 volts, the LOW BATTERY ALARM will emit a
If the battery voltage continues downward, the tone stays on and the inverter keeps running until the voltage drops below 10.0 volts. At this point the inverter locks itself off to protect your battery, but the warning tone stays on.
To reset:
Manually: Turn the power switch OFF for one second and then back ON.
Automatically: Recharge the battery above 13.0 volts.