To Store

1.Switch the unit off using power button and disconnect the power plug.

2.Remove any items being stored in the cooler. Clean inside and outside of the cooler with a damp cloth. Wipe off any moisture and allow it to thoroughly dry.

3.To refresh the air in the cooler, open the lid occasionally or place an open box of baking soda to absorb odors.

Troubleshooting before contacting Coleman for repairs.

 

 

Please check the following points

 

 

 

Problem

Possible Cause

Solution

 

On/Off button has not been pressed

Push the button until you hear a high-

 

continuously for 1 second.

pitched tone (approximately 1 second).

 

 

 

 

Electrical connections are not

Check electrical connections.

 

properly connected.

 

 

 

 

 

There are ashes or dust in the power

Clean the power supply socket.

 

supply socket.

 

 

 

 

 

A car fuse has blown.

Replace the fuse.

 

 

 

 

The DC power cable fuse or the PC

Contact The Coleman Company, Inc. Do not

Unit does

board fuse has blown due to reversed

replace the fuse yourself. An improper fuse

not turn

polarity.

will damage the product and void the war-

ranty. When installing the new DC power ca-

on

 

 

ble, make sure the polarity is not reversed.

 

 

 

 

 

 

No power to cooler.

Vehicle: turn on engine.

 

 

 

Household: check circuit brakers

 

 

 

 

 

 

The low-battery light is flashing.

Check the battery condition.

 

 

 

 

There are too many items in the

Remove some of the items from the cooler.

 

cooler, obstructing air circulation.

 

 

 

 

 

The lid is not completely closed.

Close the lid properly and lock it.

Unit does

 

 

The unit is exposed to direct sunlight,

 

not cool

Change the location of the unit.

is too close to a heat source, or is

sufficiently

being operated in an excessively hot

 

 

environment.

 

 

 

 

 

The air vents are covered.

Check both the air intake and the air outlet

 

vents. Remove any items covering the vents.

 

 

 

The lid is being opened and closed

Minimize opening and closing of the lid.

 

too often.

 

 

 

 

 

The filter is clogged.

Perform filter maintenance on Page 8.

Specifications

Operating voltage

12 VDC

 

 

Power consumption

12 VDC, 48W (4A)

Cooling temperature when

-0.4˚F to 50˚F (-18˚C to 10˚C)

empty (approx.)

( ambient temp.: 86˚F (30˚C) )

 

 

Operating temperature range

32˚F to 104˚F (0˚C to 40˚C)

 

 

Usable capacity

0.88 cu.ft (25 liters)

 

 

Dimensions (approx.)

27.3" (695 mm) W x 18.1" (460 mm) H x 13.7" (350 mm) D

 

 

Weight (approx.)

33 lbs (15 kg)

 

 

DC Power Cable

9.8 ft (3 m)

(5726-3661)

 

 

 

Household Power Supply

Converts 120 VAC to 12 VDC, 5A

(5232F640T)

 

 

 

9

10

Page 6
Image 6