Coleman 9790 manual English-19, Troubleshooting

Models: 9790

1 28
Download 28 pages 30.9 Kb
Page 20
Image 20

19 Troubleshooting

Symptom

Problem

Solution

 

 

 

Burner will not

Fuel bottle empty.

Refill fuel bottle 3/4 full with clean and

light or flame

 

fresh Coleman® fuel or approved fuels.

self-

 

 

extinguished.

 

 

 

 

 

Burner will not

Little or no pressure in fuel

Check connections for leaks and pump

light or flame is

bottle.

20 strokes.

low or flame self-

 

 

extinguished.

 

 

 

 

 

Yellow flame.

Generator not fully

A yellow flame is normal until the

 

warmed.

generator warms up. If yellow flame

 

 

persists, turn off stove, allow flame to

 

 

burn until almost extinguished and re-

 

 

open fuel valve. Colder weather or

 

 

heavy fuels such as Kerosene require

 

 

longer preheat time. Follow lighting

 

 

instructions.

 

 

 

Low heat.

Gas tip plugged.

Turn flame adjuster back and forth

 

 

several times to clean gas tip. Be sure

 

 

to use only fresh and clean fuel. If

 

 

condition persists, remove gas tip and

 

 

use tip-cleaning tool.

 

 

 

Low heat.

Incorrect gas tip.

Confirm gas tip is correct for fuel used.

 

 

 

Low heat.

Faulty generator.

Replace with a new generator. This is

 

 

a normal periodic maintenance

 

 

procedure. The generator life is

 

 

dependent on the type of fuel used.

 

 

Generator life is extended by using

 

 

clean Coleman® fuel.

 

 

 

Persistent small

Faulty generator.

Replace with a new generator.

yellow flame.

 

 

 

 

 

Sputtering yellow

Incorrect gas tip.

Confirm gas tip is correct for fuel used.

flame then very

 

 

high heat.

 

 

 

 

 

Yellow smoky

Spider webs, insects, or

Remove impingement plate to inspect

flame.

other obstruction in the

and clean the burner. Turn flame

 

burner or gas tip.

adjuster back and forth several times to

 

 

clean gas tip. If system persists,

 

 

remove and inspect gas tip (see

 

 

Section 4).

 

 

 

Irregular blue

Gas tip plugged by debris.

Remove impingement plate to inspect

flame.

 

and clean the burner. Turn flame

 

 

adjuster back and forth several times to

 

 

clean gas tip. If symptom persists,

 

 

remove and inspect gas tip (see

 

 

Section 4).

 

 

 

Irregular blue

Possible damage to

Please contact Consumer Services.

flame.

cleaning needle.

 

 

 

 

Pump does not

Pump seals are dry or

Squirt a few drops of oil in the OIL

pressurize the

worn.

HOLE in the pump cap. This will keep

liquid fuel

 

the pump functioning properly

canister.

 

(Fig. 43). If this does not correct the

 

 

problem, replace the pump seals or

 

 

purchase a new pump assembly.

 

 

 

Pump does not

Pump assembly not fully

Check pump seal for damage and hand

pressurize the

seated on liquid fuel

tighten pump assembly to liquid fuel

liquid fuel

canister.

canister.

canister.

 

 

 

 

 