Oven Setup

3.Insert the pointed end of the spit rod into the opening in the motor and rest the collar on the frame (Fig. 13). The spit rod should freely turn when the motor is turned on.

Fig. 13

4.Figure 14 illustrates the spit rod correctly installed.

Fig. 14

Oven Setup

1.To use the unit as an oven, slide the wire oven rack into the rails (Fig. 15).

NOTE: The wire oven rack must be installed correctly. The correct installation is with the lowest side of the heat deflector near the burner.

Fig. 15

Burner and Orifice

1.Proper location of the burner with respect to the venturi and orifice fitting is important. To verify the proper factory installation of the burner and venturi, look at the unit from below and locate the burner and venturi. The burner inlet must be located in line with the venturi and the orifice fitting on the end of the fuel tube

(Fig. 16).

Infra Red Burner

Venturi

Orifice Fitting

Fig. 16

Check and clean the burner/venturi tubes for insects and insect nests. A clogged tube can lead to a fire beneath the appliance.

Leak Testing

Burner and Orifice WARNING

Perform leak test outdoors.

Extinguish all open flames.

NEVER leak test when smoking.

Do not use the outdoor rotisserie until connection has been leak tested and does not leak.

Leak Testing CAUTION

SERVICE SAFETY

Keep all connections and fittings clean. Inspect propane cylinder and rotisserie propane connections for damage before attaching.

During set up, check all connections and fittings for leaks using soapy water. Bubbles indicate a leak. Never use a flame to check for leaks.