QuickSpecs

HP Compaq 8100 Elite PC

Technical Specifications

 

Small Form Factor

Convertible Minitower

Dimensions

 

 

Chassis

3.95 x 13.30 x 14.9 in

17.63 x 7.00 x 17.5 in

(H x W x D)

100 x 338 x 378.5 mm

447.8 x 177.8 x 444.5 mm

System Volume

790.26 cu in

2160 cu in

 

12.95 L

35.4 L

Tower Stand

1.12 x 7.01 x 7.87 in

N/A

(H x W x D)

28.5 x 178 x 200 mm

 

Packaging

9.00 x 19.68 x 23.38 in

22.64 x 12.72 x 24.41 in

(H x W x D)

228.6 x 499.9 x 593.85 mm

575.0 x 323 x 620 mm

System Weight*

16.72 lbs

24.54 lbs

 

7.6 kg

11.15 kg

Shipping Weight*

17.86 lbs

34.0 lbs

 

8.1 kg

15.42 kg

Max Supported Weight

77 lb

77 lbs

(desktop orientation)

35 kg

35 kg

*Configured with 1 hard drive, 1 optical drive, no diskette drive, and no PCI card.

Unit Environment and Operating Conditions

General Unit Operating Guidelines

Keep the computer away from excessive moisture, direct moisture and the extremes of heat and cold, to ensure that unit is operated within the specified operating range.

Leave a 10.2 cm (4 in) clearance on all vented sides of the computer to permit the required airflow. Never restrict airflow into the computer by blocking any vents or air intakes.

Do not stack computers on top of each other or place computers so near each other that they are subject to each other's re- circulated or preheated air.

Occasionally clean the air vents on the front, back, and any other vented side of the computer. Lint, dust and other foreign matter can block the vents and limit the airflow.

If the computer is to be operated within a separate enclosure, intake and exhaust ventilation must be provided on the enclosure, and the same operating guidelines listed above will still apply.

Temperature Range

Operating: 50° to 95° F (10° to 35° C)*

 

Non-operating: –22° to 140° F(–30° to 60° C)

Relative Humidity

Operating: 10% to 90% (non-condensing at ambient)

 

Non-operating: 5% to 95% (non-condensing at ambient)

Maximum Altitude

Operating: 10,000 ft (3048 m)

(unpressurized)

Non-operating: 30,000 ft (9144 m)

*Operating temperature is de-rated 1.0 deg C per 300 m (1000 ft) to 3000 m (10,000 ft) above sea level, no direct sustained sunlight. Maximum rate of change is 10 deg C/Hr. The upper limit may be limited by the type and number of options installed.

DA - 13524 Worldwide — Version 5 — February 3, 2010