QuickSpecs

HP Compaq dc7800 Business PC

Technical Specifications - Environmental Data

The EPE foam packaging material is made from 30 to 40% industrial recycled content. The corrugated paper packaging materials contains at least 25% post consumer recycled content.

Convertible Minitower with 80% Efficient Power Supply

System Configuration The configuration used for the Energy Consumption and Declared Noise Emissions data for the CMT Desktop model is based on a model with an Intel Core 2 Duo E6850 Processor, 1 GB memory and 160-GB HD.

Energy Consumption

AC Input Voltage at 115 VAC

AC Input Voltage at 230 VAC

AC Input Voltage at 100 VAC

 

+/- 5 VAC, 60 Hz +/- 3 Hz

+/- 5 VAC, 50 Hz +/- 3 Hz

+/- 5 VAC, 50 Hz +/- 3 Hz

Normal Operation On-

62.762 W

61.212 W

62.27 W

Idle (ENERGY STAR

 

 

 

Idle (S0))

 

 

 

ENERGY STAR “Sleep”

3.08 W

3.444 W

3.07 W

(S3) (Wake On LAN

 

 

 

(WOL) Enabled)

 

 

 

ENERGY STAR “Sleep”

3.09 W

3.42 W

3.05 W

(S3) (Wake On LAN

 

 

 

(WOL) Disabled)

 

 

 

ENERGY STAR

1.53 W

1.79 W

1.46 W

“Standby” (Off) (S5)

 

 

 

(Wake On LAN (WOL)

 

 

 

Enabled)

 

 

 

ENERGY STAR

0.79 W

1.08 W

0.77 W

“Standby” (Off) (S5)

 

 

 

(Wake On LAN (WOL)

 

 

 

Disabled)

 

 

 

Heat Dissipation*

AC Input Voltage at 115 VAC

AC Input Voltage at 230 VAC

AC Input Voltage at 100 VAC

 

+/- 5 VAC, 60 Hz +/- 3 Hz

+/- 5 VAC, 50 Hz +/- 3 Hz

+/- 5 VAC, 50 Hz +/- 3 Hz

Normal Operation On-

214.143 BTU/hr

208.855 BTU/hr

212.465 BTU/hr

Idle (ENERGY STAR

 

 

 

Idle (S0))

 

 

 

ENERGY STAR “Sleep”

10.508 BTU/hr

11.75 BTU/hr

10.474 BTU/hr

(S3) (Wake On LAN

 

 

 

(WOL) Enabled)

 

 

 

ENERGY STAR “Sleep”

10.543 BTU/hr

11.669 BTU/hr

10.406 BTU/hr

(S3) (Wake On LAN

 

 

 

(WOL) Disabled)

 

 

 

ENERGY STAR

5.22 BTU/hr

6.107 BTU/hr

4.981 BTU/hr

“Standby” (Off) (S5)

 

 

 

(Wake On LAN (WOL)

 

 

 

Enabled)

 

 

 

ENERGY STAR

2.695 BTU/hr

3.684 BTU/hr

2.627 BTU/hr

“Standby” (Off) (S5)

 

 

 

(Wake On LAN (WOL)

 

 

 

Disabled)

 

 

 

*Heat dissipation is calculated based on the measured watts, assuming the service level is attained for one hour. This product is in compliance with US executive order 13221, WOL (wake on LAN) disabled.

DA - 12744 Worldwide QuickSpecs — Version 13 — 12.14.2007

Page 50

Page 50
Image 50
Compaq dc7800 manual Convertible Minitower with 80% Efficient Power Supply