Compaq manual Technical Specifications, QuickSpecs, HP Compaq dc7800 Business PC, Page

Models: dc7800

1 53
Download 53 pages 14 Kb
Page 19
Image 19
Technical Specifications

QuickSpecs

HP Compaq dc7800 Business PC

Technical Specifications

Unit Environment and Operating Conditions

Ultra-slim Desktop

Small Form Factor

Convertible Minitower

General Unit Operating Guidelines

Keep the computer away from excessive moisture, direct moisture and the extremes of heat and cold, to ensure that unit is operated within the specified operating range.

Leave a 10.2 cm (4 in) clearance on all vented sides of the computer to permit the required airflow. Never restrict airflow into the computer by blocking any vents or air intakes.

Do not stack computers on top of each other or place computers so near each other that they are subject to each other's re-circulated or preheated air.

Occasionally clean the air vents on the front, back, and any other vented side of the computer. Lint, dust and other foreign matter can block the vents and limit the airflow.

If the computer is to be operated within a separate enclosure, intake and exhaust ventilation must be provided on the enclosure, and the same operating guidelines listed above will still apply.

Temperature Range

Operating: 50° to 95° F (10° to 35° C)*

 

Non-operating: -22° to 140° F(-30° to 60° C)

Relative Humidity

Operating: 10% to 90% (non-condensing at ambient)

 

Non-operating: 5% to 95% (non-condensing at ambient)

Maximum Altitude

Operating: 10,000 ft (3048 m)

(unpressurized)

Non-operating: 30,000 ft (9144 m)

*Operating temperature is de-rated 1.0 deg C per 300 m (1000 ft) to 3000 m (10,000 ft) above sea level, no direct sustained sunlight. Maximum rate of change is 10 deg C/Hr. The upper limit may be limited by the type and number of options installed.

Power Supply

Ultra-slim Desktop

Small Form Factor

Convertible Minitower

Power Supply

135 watt External custom power

240 watt custom power supply –

365 watt custom power supply –

 

supply – Active PFC)

Active PFC

Active PFC)

Operating Voltage Range

90 – 264 VAC

90 – 264 VAC

90 – 264 VAC

Rated Voltage Range

100 – 240 VAC

100 – 240 VAC

100 – 240 VAC

Rated Line Frequency

50/60 Hz

50/60 Hz

50/60 Hz

Operating Line

47 – 63 Hz

47 – 63 Hz

47 – 63 Hz

Frequency Range

 

 

 

Rated Input Current

N/A

4A

6A

Rated Input Current with

1.5A

3.5A

5A

80% Efficient* Power

 

 

 

Supply

 

 

 

Current Leakage

< 275 µA

< 275 µA

< 450 µA

(NFPA 99)

 

 

 

System Heat Dissipation

N/A

Typical 198 btu/hr

Typical 222 btu/hr

 

 

(50 kg-cal/hr)

(56 kg-cal/hr)

 

 

Maximum 1260 btu/hr

Maximum 1916 btu/hr

 

 

(318 kg-cal/hr

(483 kg-cal/hr)

System Heat Dissipation

Typical 133 btu/hr

Typical 150 btu/hr

Typical 171 btu/hr

with 80% Efficient* Power

(33.5 kg-cal/hr)

(38 kg-cal/hr)

(43 kg-cal/hr)

Supply

Maximum 549 btu/hr

Maximum 1024 btu/hr

Maximum 1557 btu/hr

 

(132 kg-cal/hr)

(258 kg-cal/hr)

(392 kg-cal/hr)

Power Supply Fan

N/A

80mm variable speed

92mm variable speed

ENERGY STAR

X

X

X

Compliant

 

 

 

with 80% Efficient* Power

 

 

 

Supply

 

 

 

 

 

DA - 12744 Worldwide QuickSpecs — Version 13 — 12.14.2007

Page 19
Page 19
Image 19
Compaq manual Technical Specifications, QuickSpecs, HP Compaq dc7800 Business PC, watt custom power supply, Page