CompuSTAR 1W900FMR manual 1-7*7

Models: 1W900FMR

1 6
Download 6 pages 23.91 Kb
Page 2
Image 2
1-7 (*7)

1-7 (*7)

Unlock / Disarm With

Unlock, Factory Disarm,

Factory Disarm, Trunk

Trunk Release Only

 

 

V

 

 

V

 

 

V

 

Trunk Release

and Trunk Release

Release Only

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1-8

Locking while in Passive

Passive locking w/

No Passive Locking w/

 

 

 

V

 

 

V

 

 

V

 

Arming

Passive Arming

Passive Arming

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1-9 (*3)

Ignition controlled door

Off

On

RPM Locks (Remote

 

 

V

 

 

V

 

 

V

 

locks

Start Only)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Auto Relock (If a door is

 

 

 

 

 

 

 

 

 

 

 

 

 

1-10

not opened within this

Off

30 sec

60 sec

5 min

 

V

 

 

V

 

 

V

 

 

amount of time.)

 

 

 

 

 

 

 

 

 

 

 

 

 

2-2 (*5)

Turbo mode.

Off

2 Min

1Min

4 Min

 

V

 

 

V

 

 

 

 

2-5 (*4)

Cold Start with

Off

On

 

 

 

V

 

 

V

 

 

 

 

Thermistor Assembly

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Timer Start, or,

3 Hour (4 minute

1.5 Hour(4 minute

 

 

 

 

 

 

 

 

 

 

 

2-6 (*4)

Minimum Interval

runtime, double for

runtime, double for

 

 

 

V

 

 

V

 

 

 

 

 

Between Cold Starts

Diesel)

Diesel)

 

 

 

 

 

 

 

 

 

 

 

2-7

Remote Start Runtime

15 Min

25 Min

45 Min

3 Min

 

V

 

 

V

 

 

 

 

2-8 (*4)

Temperature of Cold

Off

-10° C / 14° F

-5° C / 23° F

0° C / 32° F

 

V

 

 

V

 

 

 

 

Starting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2-9 (*4)

Temperature of Hot

Off

30° C / 86° F

35° C / 95° F

40° C / 104° F

 

V

 

 

V

 

 

 

 

Starting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Turbo, Remote Start

 

 

 

 

 

 

 

 

 

 

 

 

 

2-11 (*6)

Runtime Extension w/

No

Yes

 

 

 

V

 

 

V

 

 

 

 

 

#1 for 2 seconds

 

 

 

 

 

 

 

 

 

 

 

 

 

3-1

Parking lights While

Constant Output

Flashing Output

Off

 

 

V

 

 

V

 

 

 

 

Remote Started

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3-4

Starter-Kill relay.

Anti-Grind

Anti-Grind + Starter Kill

Anti-Grind +

 

 

V

 

 

V

 

 

 

 

Passive Starter Kill

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3-5 (*8)

Anti-Jacking

Starter-kill

Ignition-Kill

 

 

 

V

 

 

 

 

 

V

 

(no Anti-Grind)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3-6

Factory Alarm Option

Off

On (Starter Only)

 

 

 

 

 

 

V

 

 

 

 

3-7

Siren Duration (Upon

30 sec

60 sec

120 Sec

Chirps for 20 seconds

 

V

 

 

 

 

 

V

 

Alarm Trigger)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3-8

Horn Output

On Double Lock Only

On Lock and Unlock

On Lock, Unlock, and

On Double Lock and

 

 

 

 

V

 

 

 

 

Start

Start

 

 

 

 

 

 

 

 

 

 

Key 5 times, or Remote

Key 5 times or Remote

Secure Valet(Default

 

 

 

 

 

 

 

 

 

 

3-10 (*2)

Valet

(I+III) while Ignition is

 

 

V

 

 

V

 

 

V

 

(I+III)

code 3,3)

 

 

 

 

 

 

 

 

 

On

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4-5 (*1)

Secure Aux Output (1

On

Off

 

 

 

V

 

 

V

 

 

V

 

and 2 Only)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Lock Button (0.5 Sec.) – Tapping this button for a split second will lock/arm your CompuStar system. Your parking lights will flash once when you tap this button.

Lock Button (3.5 Sec.) – This button activates the panic mode on your system when held down for 3.5 seconds. Holding down the Lock button for 3.5 seconds will panic the siren. You can turn panic mode off by tapping the Unlock button. This Panic mode will also activate the Anti-Jack mode. The Anti-Jack mode will require additional installation. See Anti-Jacking under Additional Features below.

Unlock Button (0.5 Sec.) – Tapping this button for a split second will lock/arm your CompuStar system.

Your parking lights will flash twice when you tap this button.

Trunk Button (0.5 Sec.) - Tapping the Trunk button activates Aux 1. These can be used to activate side doors, window modules, etc. By default, the Key button can only be activated as Secure Aux to prevent accident activation. Click IV before you activate the Trunk button. This can be changed – ask your installer. You may want to keep Secure Aux if you connect Aux to open side doors.

Trunk Button (2.5 Sec.) – When you hold the Trunk button for 2.5 seconds you can release your trunk. By default when you release the trunk the CompuStar will also disarm and unlock the doors.

Key Button (0.5 Sec.) - Tapping the Key button activates Aux 2. These can be used to activate side doors, window modules, etc. By default, the Key button can only be activated as Secure Aux to prevent accident activation. Click IV before you activate the Key button. This can be changed – ask your installer. You may want to keep Secure Aux if you connect Aux to open side doors.

2

Page 2
Image 2
CompuSTAR 1W900FMR manual 1-7*7