Chapter 4: Appendix D - |
|
|
| |||||
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| |
| Table 7: |
|
| |||||
|
|
|
|
|
|
|
|
|
| Port | SLIM | Switch | Port |
| SLIM | Switch |
|
| number | socket | block | number |
| socket | block |
|
| 1 | SM1 | S4 | 9 |
| SM3 | S4 |
|
| 2 | SM1 | S3 | 10 |
| SM3 | S3 |
|
| 3 | SM1 | S2 | 11 |
| SM3 | S2 |
|
| 4 | SM1 | S1 | 12 |
| SM3 | S1 |
|
| 5 | SM2 | S4 | 13 |
| SM4 | S4 |
|
| 6 | SM2 | S3 | 14 |
| SM4 | S3 |
|
| 7 | SM2 | S2 | 15 |
| SM4 | S2 |
|
| 8 | SM2 | S1 | 16 |
| SM4 | S1 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Table 8:
Switch |
| Configuration | Configuration |
Position |
| (when OFF) | (when ON) |
1 |
| TxD load is removed | TxD load enabled (150 ohms) |
2 |
| RTS load is removed | RTS load enabled (150 ohms) |
3 & 4 |
| RxD disconnected from | RxD connected to bias and |
|
| bias and load circuits | load circuits |
|
|
|
|
|
| Note: These two switches |
|
|
| MUST be used together |
|
|
|
|
|
5 |
| RxD load is AC (150 | RxD load is DC (150 ohms |
|
| ohms in series with 50 nF | and < 50 metres in length) |
|
| and > 50 metres in length) |
|
6 |
| CTS load is AC (150 | CTS load is DC (150 ohms) |
|
| ohms in series with 50 nF) |
|
Technical Tip: We recommend that you set the switches 3, 4 and 5 on the