DOCUMENT 1025

 

 

REV. B

 

Instruction Manual

 

 

 

 

 

 

AGS-LED

 

 

 

858 LED Series

 

 

 

Sizes 1, 2, 3, 4 and 5

 

 

 

 

 

 

PROBLEM

POSSIBLE CAUSE

CORRECTIVE ACTION

 

 

 

 

 

 

 

MODULE(s) (See Sec 10.10)

 

 

 

 

 

(P.10) Upon

Incorrect LED Power Supply

Verify/Set Power Supply

 

applying power,

Circuit Board Switch

Board Switches and jumpers

 

sign

Configuration

are set according to Table 1

 

momentarily

 

(Ferro CCR) or Table 2 (Series

 

lights and then

 

CCR)

 

turns off.

 

 

 

 

 

 

 

(P.11) Upon

LED MODULE Voltage has

Replace any LED

 

applying power,

dropped 25% below the calibrated

MODULE(s) with non-lit

 

sign

output voltage (See Table 12).

LEDs and re-calibrate the LED

 

momentarily

 

Power Supply. (See Sections

 

lights and then

 

10.10 & 10.11)

 

turns off.

 

 

 

 

 

 

 

(P.12) Upon

LED MODULE Voltage is greater

Verify/Set Power Supply

 

applying power,

than 125% of the expected

Board Switches and jumpers

 

sign

calibrated output voltage (See

are set according to Table 1

 

momentarily

Table 12).

(Ferro CCR) or Table 2 (Series

 

lights and then

 

CCR)

 

turns off.

 

 

 

 

 

 

 

(P.13) Sign

Incorrect LED Power Supply

Verify/Set Jumpers JP1 and

 

flickering

Circuit Board Jumper Setting.

JP2 according to the Table 1

 

 

 

(FERRO CCR) or Table 2

 

 

 

(Series CCR)

 

 

 

 

 

(P.14) Sign

Incorrect Isolation Transformer

Replace with Isolation

 

flickering

 

transformer that matches sign

 

 

 

type, size, #modules. (See

 

 

 

Tables 3-8)

 

 

 

 

 

9

Page 17
Image 17
Cooper Bussmann 858 instruction manual Ccr