| DOCUMENT 1025 | |
|
| REV. B | |
| Instruction Manual |
|
|
|
|
| |
|
|
| |
| 858 LED Series |
|
|
| Sizes 1, 2, 3, 4 and 5 |
|
|
|
|
|
|
PROBLEM | POSSIBLE CAUSE | CORRECTIVE ACTION |
|
|
|
|
|
|
| MODULE(s) (See Sec 10.10) |
|
|
|
|
|
(P.10) Upon | Incorrect LED Power Supply | Verify/Set Power Supply |
|
applying power, | Circuit Board Switch | Board Switches and jumpers |
|
sign | Configuration | are set according to Table 1 |
|
momentarily |
| (Ferro CCR) or Table 2 (Series |
|
lights and then |
| CCR) |
|
turns off. |
|
|
|
|
|
|
|
(P.11) Upon | LED MODULE Voltage has | Replace any LED |
|
applying power, | dropped 25% below the calibrated | MODULE(s) with |
|
sign | output voltage (See Table 12). | LEDs and |
|
momentarily |
| Power Supply. (See Sections |
|
lights and then |
| 10.10 & 10.11) |
|
turns off. |
|
|
|
|
|
|
|
(P.12) Upon | LED MODULE Voltage is greater | Verify/Set Power Supply |
|
applying power, | than 125% of the expected | Board Switches and jumpers |
|
sign | calibrated output voltage (See | are set according to Table 1 |
|
momentarily | Table 12). | (Ferro CCR) or Table 2 (Series |
|
lights and then |
| CCR) |
|
turns off. |
|
|
|
|
|
|
|
(P.13) Sign | Incorrect LED Power Supply | Verify/Set Jumpers JP1 and |
|
flickering | Circuit Board Jumper Setting. | JP2 according to the Table 1 |
|
|
| (FERRO CCR) or Table 2 |
|
|
| (Series CCR) |
|
|
|
|
|
(P.14) Sign | Incorrect Isolation Transformer | Replace with Isolation |
|
flickering |
| transformer that matches sign |
|
|
| type, size, #modules. (See |
|
|
| Tables |
|
|
|
|
|
9