Sizes 1, 2, 3, 4 and 5
Turn off power to the sign by turninng off the corresponding Constant Current Regulator (CCR) power. (WARNING: Wait five minutes after sign power is turned off to service the sign. This will allow any residual high voltage stored i n Power Supply PCB components to bleed off.) With your multimeter set to DC Volts, verify that the Power Supply Output Voltage is less than
Remove the black return cable connnector from the last LED MODULE output cable connnector (see Figures
Turn off main power to the sign. Wait five minutes for the power supply voltages to dissipate. Verify that the output voltage is less than
10.8Checking the Second LEED MODULE
WARNING
WARNING:
Failure to t urn off power to the sign and wait five minutes could result in severe injury or death.
Turn off power to the sign by turninng off the corresponding Constant Current Regulator (CCR) power. (WARNING: Wait five minutes after sign power is turned off to service the sign. This will allow any residual high voltage stored i n Power Supply PCB components to bleed off.) With your multimeter set to DC Volts, verify that the Power Supply Output Voltage is less than
Remove the black return cable connnector from the last LED MODULE output cable connnector (see Figure 20). Replace the output cable conneector in the second LED MODULE with the black return cable connector. Turn on main power to the sign. If both LED MODULES momentarily lightt and then turn off
13