11

12

MEDIUM COMPETITION SITE LIGHTING

MEDIUM COMPETITION DISPLAY

When your automotive dealership lot is neighbored by service stations or large national retailers medium competition lighting levels are recommended. Create a front row feature display along the roadway with primary traffic flow. To prevent obstructing the view of displayed vehicles, mount poles at grade [25' pole/fixture mounting height]. The remaining areas of the dealership displaying vehicles are considered general merchandise areas. To protect merchandise, mount poles on a 2.5' concrete base [25' pole, 27 1/2' fixture mounting height].

General Merchandise

 

 

 

 

 

 

Medium

Horizontal

 

 

 

 

 

 

Maintained

Uniformity

 

 

 

 

 

 

 

 

 

 

Area to Illuminate

 

 

 

 

Levels [fc]

[Max.Min.]

 

Parking and Circulation [Non-Merchandising Area]

7

10:1

 

General Merchandise [Main Automotive Display Lot]

30

5:1

 

Featured Displays [Front Row and Display Stands]

 

50

3:1

 

 

 

Arrow denotes optical orientation.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Footcandles [fc]

 

 

 

 

 

 

 

Front Row

 

 

 

 

 

 

 

 

70

46

30

19

12

8

5

3

 

1000W MH FLAT GLASS FRONT ROW DISPLAY

IESNA recommends 50 FC average illuminance for areas of medium competition.

 

 

 

 

Mounting Height [ft.]

 

25

 

 

 

 

Spacing [ft.]

 

60

 

 

 

 

Maintained Average FC

61.9

 

 

 

 

 

Uniformity

 

2.45

POLE FIXTURE COMBINATION ORDERING LOGIC

 

 

 

 

 

 

Distribution

Fixture Configuration

Product Family 1

80 MPH

90 MPH

100 MPH 2

 

 

Automotive Front Row [AF]

2 @ 180°

Talon [TLL]

TLL21KMFF25XX 3

TLL21KMFF25XX 3

TLL21KMFF25XX0 4

 

 

 

Galleria Square [GSM]

GSM21KMFF25XX 3

GSM21KMFF25XX 3

GSM21KMFF25XX0 4

 

 

Galleria Round [GRM]

GRM21KMFF25XX 3

GRM21KMFF25XX 3

GRM21KMFF25XX 3

 

 

CLM

CLM21KMFF25XX 3

CLM21KMFF25XX 3

CLM21KMFF25XX0 4

 

NOTES: 1 Pole fixture combination includes pole, fixtures, lamp, and mounting hardware. Fixture supplied with 5-Tap [120/208/240/277/480V] ballast wired 480V. 2 0 noted where needed to designate a heavier gauge pole. 3 Combination supplied with SSS5A25S square straight steel shaft, anchor bolts [AB1], template [TMP1] and base cover. Replace XX with color designation [page 4]. 4 Combination supplied with SSS5M25S square straight steel shaft, anchor bolts [AB1], template [TMP1] and base cover. Replace XX with color designation [page 4].

750W MH FLAT GLASS FRONT ROW DISPLAY

IESNA recommends 50 FC average illuminance for areas of medium competition.

 

 

 

 

Mounting Height [ft.]

 

25

 

 

 

 

Spacing [ft.]

 

50

 

 

 

 

Maintained Average FC

59.8

 

 

 

 

 

Uniformity

 

1.23

POLE FIXTURE COMBINATION ORDERING LOGIC

 

 

 

 

 

 

Distribution

Fixture Configuration

Product Family 1

80 MPH

90 MPH

100 MPH 2

 

 

Automotive Front Row [AF]

2 @ 180°

Talon [TLL]

TLL275PFF25XX 3

TLL275PFF25XX 3

TLL275PFF25XX0 4

 

 

 

Galleria Square [GSM]

GSM275PFF25XX 3

GSM275PFF25XX 3

GSM275PFF25XX0 4

 

 

Galleria Round [GRM]

GRM275PFF25XX 3

GRM275PFF25XX 3

GRM275PFF25XX 3

 

 

CLM

CLM275PFF25XX 3

CLM275PFF25XX 3

CLM275PFF25XX0 4

 

NOTES: 1 Pole fixture combination includes pole, fixtures, lamp, and mounting hardware. Fixture supplied with 5-Tap [120/208/240/277/480V] ballast wired 480V. 2 0 noted where needed to designate a heavier gauge pole. 3 Combination supplied with SSS5A25S square straight steel shaft, anchor bolts [AB1], template [TMP1] and base cover. Replace XX with color designation [page 4]. 4 Combination supplied with SSS5M25S square straight steel shaft, anchor bolts [AB1], template [TMP1] and base cover. Replace XX with color designation [page 4].

Page 12
Image 12
Cooper Lighting ADH080747 manual Medium Competition Site Lighting, Medium Competition Display