HIGH COMPETITION SITE LIGHTING

General Merchandise

Front Row

POLE FIXTURE COMBINATION ORDERING LOGIC

HIGH COMPETITION DISPLAY

When your automotive dealership lot is neighbored by well illuminated dealerships or service stations high competition lighting levels are recommended. Create a front row feature display along the roadway with primary traffic flow. To prevent obstructing the view of displayed vehicles, mount poles at grade [25' pole/fixture mounting height]. The remaining areas of the dealership displaying vehicles are considered general merchandise areas. To protect merchandise, mount poles on a 2.5' concrete base [25' pole, 27 1/2' fixture mounting height].

 

 

 

 

 

 

 

High

Horizontal

 

 

 

 

 

 

 

Maintained

Uniformity

Area to Illuminate

 

 

 

 

Levels [fc]

[Max.Min.]

Parking and Circulation [Non-Merchandising Area]

10

10:1

General Merchandise [Main Automotive Display Lot]

50

5:1

Featured Displays [Front Row and Display Stands]

 

75

3:1

 

Arrow denotes optical orientation.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Footcandles [fc]

 

 

 

 

 

 

 

80

52

34

22

14

9

6

4

 

1000W MH FLAT GLASS ENHANCED FRONT ROW DISPLAY

Areas with extremely high visual competition could use enhanced illumination levels between 75-100 FC.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mounting Height [ft.]

25

Spacing [ft.]

40

Maintained Average FC

94.5

Uniformity

1.22

Distribution

Fixture Configuration

Product Family 1

80 MPH

90 MPH

100 MPH 2

Automotive Front Row [AF]

2 @ 180°

Talon [TLL]

TLL21KMFF25XX 3

TLL21KMFF25XX 3

TLL21KMFF25XX0 4

 

 

Galleria Square [GSM]

GSM21KMFF25XX 3

GSM21KMFF25XX 3

GSM21KMFF25XX0 4

 

 

Galleria Round [GRM]

GRM21KMFF25XX 3

GRM21KMFF25XX 3

GRM21KMFF25XX 3

 

 

CLM

CLM21KMFF25XX 3

CLM21KMFF25XX 3

CLM21KMFF25XX0 4

NOTES: 1 Pole fixture combination includes pole, fixtures, lamp, and mounting hardware. Fixture supplied with 5-Tap [120/208/240/277/480V] ballast wired 480V. 2 0 noted where needed to designate a heavier gauge pole. 3 Combination supplied with SSS5A25S square straight steel shaft, anchor bolts [AB1], template [TMP1] and base cover. Replace XX with color designation [page 4]. 4 Combination supplied with SSS5M25S square straight steel shaft, anchor bolts [AB1], template [TMP1] and base cover. Replace XX with color designation [page 4].

1000W MH FLAT GLASS ENHANCED MERCHANDISE DISPLAY

Areas with extremely high visual competition could use enhanced illumination levels between 50-60 FC.

 

 

 

 

Mounting Height [ft.]

 

27.5

 

 

 

 

Spacing [ft.]

 

55

 

 

 

 

Maintained Average FC

54.6

 

 

 

 

Uniformity

 

1.15

POLE FIXTURE COMBINATION ORDERING LOGIC

 

 

 

 

 

 

Distribution

Fixture Configuration

Product Family 1

80 MPH

90 MPH

100 MPH

 

 

Area Round [AR]

3 @ 90°

Talon [TLL]

TLL31KMRF25XX 2

TLL31KMRF25XX 2

TLL31KMRF25XX 2

 

 

 

Galleria Square [GSM]

GSM31KMRF25XX 2

GSM31KMRF25XX 2

GSM31KMRF25XX 2

 

 

Galleria Round [GRM]

GRM31KMRF25XX 2

GRM31KMRF25XX 2

GRM31KMRF25XX 2

 

 

CLM

CLM31KMRF25XX 2

CLM31KMRF25XX 2

CLM31KMRF25XX 2

 

NOTES: 1 Pole fixture combination includes pole, fixtures, lamp, and mounting hardware. Fixture supplied with 5-Tap [120/208/240/277/480V] ballast wired 480V. 2 Combination supplied with SSS5M25S square straight steel shaft, anchor bolts [AB1], template [TMP1] and base cover. Replace XX with color designation [page 4].

Page 9
Image 9
Cooper Lighting ADH080747 manual High Competition Site Lighting, High Competition Display