Installation Instructions

Sheet 1 of 3

Vault

 

C-Scroll

 

Roundel

These installation instructions are valid with the above Ametrix styles.

Large, OUTDOOR

P1R

(Pendant, 1-way, Remote ballast)

Visor and Non-Visor

Warning: Before starting any work ensure that all sources of power are turned off. All work must meet local/national codes and be performed by a certified electrician. Do not mount fixtures vertically.

Exploded view and part call-out

1Securing fixture to pendant

Mounting plate

Appropriate fasteners (by others)

(2x)

Mounting plate Yoke

Canopy

#10-32 End screw (2x)

#10-32 x 3/8" Pan head screw (2x)

1/4-20x 3/4" Hex cap screw

Wire connector

#6-32 x 1/4" Flat head screw

End cap

End screw (2x)

Fixture wire

1/4-20 x 3/4" Hex cap screw (2x)

(2x)

1. Begin by removing end screw, #6-32 x 1/4" Flat head screw

and end cap from one side of Yoke and remove fixture head.

Attention:

Large fixtures require additional bracing/structure

around J-box to support fixture.

2Mounting and wiring fixture

J-box

Use additional bracing

(by others)

around J-box to support

 

Appropriate

fixture.

fasteners

 

(by others)

#6-32 x 3/8"

(4x)

Pan head screws

 

Canopy

(2x)

1.Loosen #6-32x 3/8" Pan head screws and allow canopy to slide down pendant.

2.Feed wires from J-box through wire ways in mounting plate and secure fixture to bracing around J-box.

3.Attach appropriate wires and ensure all connections are properly matched.

4.Replace canopy and secure with both #6-32 x3/8" Pan head screws.

2.

Mount yoke to pendant with both 1/4-20 Hex cap screws.

3.

Feed fixture wire through connector in pendant up through

 

mounting plate and reattach fixture head to yoke.

3Sealing the fixture

#6-32 x 1/2" Socket cap screw (2x)

Wire seal

#6-32 x 5/8"

Socket cap screw

1.To seal fixture, secure all socket cap screws according to sequence and torque specifications on supplementry sheet.

2.Ensure a smooth and sealed connection at wire seal.

3.For aiming instructions refer to aiming supplementry sheet

ADY071473 REV A(ECN070347)

Page 1
Image 1
Cooper Lighting ADY071473 installation instructions Large, Outdoor, P1R, Visor and Non-Visor, Installation Instructions