Cooper Lighting Architectural Area Luminaire manual Specification Features, Mounting, Construction

Models: Architectural Area Luminaire

1 24
Download 24 pages 53.68 Kb
Page 14
Image 14
SPECIFICATION FEATURES

13

14

SPECIFICATION FEATURES

MOUNTING

Extruded 8" [TLM Talon Medium] or 10 1/2" [TLL Talon Large] aluminum arm includes internal bolt guides allowing for easy positioning of fixture during installation to pole or wall surface. Standard single carton packaging of housing, square pole arm and round pole adapter for contractor friendly arrival of product on site.

CONSTRUCTION

Heavy-wall, die-cast low-copper alloy aluminum construction with integral reveal channels along top surface of housing to promote heat extraction and prolong electrical component life. Internal cast-in wall separates optical and electrical chambers, allowing components to operate cooler. One-piece heavy-wall,

OPTICAL SYSTEMS

Choice of 14 high efficiency optical systems utilizing horizontal and vertical lamp orientations, including five [5] optional high efficiency segmented optical systems constructed of premium 95% reflective anodized aluminum sheet. Optical segments are rigidly mounted inside a thick gauge aluminum housing for superior protection. All segment faces are clean of rivet heads, tabs or other means of attachment which may cause streaking in the light distribution. Standard with mogul-base socket for HPS and 175-1000W MH. Standard with medium-base socket for 150W MH and below. All optical modules feature quick disconnect wiring plugs and are field rotatable in 90° increments.

ELECTRICAL

TLM offered standard with ballast and related electrical componentry hard mounted to die-cast housing for optimal heat transfer and improved operating efficiency. TLM optional and TLL standard, electrical componentry mounted to a swing-down galvanized steel power tray with integral handle. Electrical disconnects allow tray to be completely removed from the housing providing ample hand and tool room for attachment of fixture during installation.

die-cast aluminum door frame with integral cast-in gasket channel seals optical chamber to an IP65 rating.

Stainless steel latches and hinges.

 

 

TALON MEDIUM [TLM]

 

TALON LARGE [TLL]

 

Lamp

Standard Door

70-200W

250-400W

Lamp

250-1000W

Distribution

Orientation

Configuration

Lens Type

Lens Type

Orientation

Lens Type

2F

Horizontal

Recessed

Flat/Sag

Flat/Sag

Horizontal

Flat/Sag

2S

Horizontal

Recessed

Flat/Sag

Flat/Sag

Horizontal

Flat/Sag

3F

Horizontal

Recessed

Flat/Sag

Flat/Sag

Horizontal

Flat/Sag

3S

Horizontal

Recessed

Flat/Sag

Flat/Sag

Horizontal

Flat/Sag

4F

Horizontal

Recessed

Flat/Sag

Flat/Sag

Horizontal

Flat/Sag

4S

Horizontal

Recessed

Flat/Sag

Flat/Sag

Horizontal

Flat/Sag

5F

Horizontal

Recessed

Flat/Sag

Flat/Sag

Horizontal

Flat/Sag

5S

Horizontal

Recessed

Flat/Sag

Flat/Sag

Horizontal

Flat/Sag

SL

Horizontal

Recessed

Flat/Sag

Flat/Sag

Horizontal

Flat/Sag

AR

Vertical

Deep

Flat/Sag

Sag

Vertical

Flat/Sag

AS

Vertical

Deep

Flat/Sag

Sag

Vertical

Flat/Sag

3V

Vertical

Deep

Flat/Sag

Sag

Vertical

Flat/Sag

4V

Vertical

Deep

Flat/Sag

Sag

Vertical

Flat/Sag

AF

Horizontal

Recessed

Flat/Sag

Flat/Sag

Vertical

Flat/Sag

Page 14
Image 14
Cooper Lighting Architectural Area Luminaire Specification Features, Mounting, Construction, Optical Systems, Electrical