Cooper Lighting GC SERIES specifications Cooper Lighting - Metalux, Gc Series, Static, Recessed

Models: GC SERIES

1 1
Download 1 pages 55.66 Kb
Page 1
Image 1
STATIC

STATIC

COOPER LIGHTING - METALUX®

D E S C R I P T I O ND I M E N S I O N S

RECESSED

GC SERIES

1 ' x 4 ' , 2 ' x 2 ' , 2 ' x 4 ' 2 0 " x 4 8 " Tr o f f e r

1 , 2 , 3 a n d 4 L a m p

D E E P S P E C I F I C AT I O N G R A D E R E C E S S E D

S TAT I C T R O F F E R

The Specification GC Series features a nominal 5-1/2" deep (1x4), 4-1/2" deep (2x2, 2x4, 20x48), para-contoured fixture housing, high reflectivity and optimum lamp to lens spacing. The Series produces total uniformity of light in the luminous area and is compatible with all of today’s popular ceiling systems. The finish provides high reflectance. The GC Series is an excellent choice for commercial, office spaces, schools, hospitals or retail merchandising areas.

2' x 2', 2' x 4'

20" x 48"

1' x 4'

Equipped with energy

 

saving ballasts/complies

 

with federal energy

 

efficiency standards

Reinforced quadrasealed

 

flat white steel door,

 

mitered corners

Spring loaded latch

Deep “V” raceway/ballast

 

cover distributes light

NOMINAL SIZE

A

B

1' x 4'

11-3/4" (298mm)

5-5/8" (143mm)

2' x 2'

23-3/4" (603mm)

4-5/8" (116mm)

2' x 4'

23-3/4" (603mm)

4-5/8" (116mm)

20" x 48"

19-3/4" (502mm)

4-5/8" (116mm)

O R D E R I N G I N F O R M AT I O N

S A M P L E N U M B E R : 2 G C - 2 3 2 A - 1 2 0 V - E B 8 1 - U

402

(6)

uniformly across lens

• Lamp to lens spacing

produces high comfort

photometrics

• Four auxiliary fixture end

suspension points provided

• End plate grid lock

feature

• For information on flanged

fixture, including ceiling

opening size, see Technical

Section.

• UL/CUL Listed. Suitable for

damp locations.

Width

2'=2' width Blank=1' width or 20" width

Trim Type

G=Grid/Lay-in – Standard

G=Concealed T

G=Slot Grid (1)

F=Flange Trim

MZ=Modular Trim

EMZ=Modular Trim

(Extended Swing Arm)

Series

C=Specification Deep Troffer

Doorframes

Standard=Flat White Steel Door

(Leave Blank)

FA=Flat White Extruded

Aluminum Door

RA=3/8" Regressed White

Extruded Aluminum Door

FAN=Flat Natural Extruded

Aluminum Door

RAN=3/8" Regressed Natural

Extruded Aluminum Door

FAB=Flat Black Extruded

Aluminum Door

RAB=3/8" Regressed Black

Extruded Aluminum Door

Silver Finish

SS=Silver-Lining

Housing and

Ballast Cover

2048=20" Width x 48"

Length

Number of Lamps (2) 1, 2, 3, or 4 Lamps

(Not included)

Wattage (Length)

U3=40W T12 (24") U6T8=32W T8 (24") 20=20W T12 (24")

17=17W T8 (24") U15/8=31W T8 (24") BX40=40W Biax (24") 40=40W T12 (48")

32=32W T8 (48")

Shielding

A=#12 PatternAcrylic

(See Lens and Louver Tables for additional shielding options)

Voltage(3)

120V=120 Volt

277V=277 Volt

347V=347 Volt

UNV=Universal

Voltage 120-277 (4)

Options

GL=Single Element Fuse

GM=Double Element Fuse

Lamps - for lamps installed, see lamp options table Flex - for flex installed, see flex ordering table Emergency - for EM installed, see EM options table

Options

Packaging

(See Options

U=Unit Pack

Section)

PAL=Job Pack,

 

out of carton

 

PALC=Job

Ballast Type (3)

Pack, in carton

Blank=Standard Magnetic Ballast (Biax & 20W) LE3=T12 Magnetic Energy Saving

ER8 = T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%

No. of Ballast 1, 2 or 3

EB8 = T8 Electronic Instant Start. Total Harmonic Distortion < 10%

No. of Ballast 1, 2 or 3

EB8 /PLUS= T8 Electronic Instant Start. High

No. of

Ballast Factor >1.13. Total Harmonic

Distortion < 20%

Ballast

 

1, 2 or 3

 

EB5 = T5 Biax Electronic Instant Start. Total Harmonic Distortion < 20%

No. of Ballast 1, 2 or 3

TEB5 =T5 Biax Electronic Instant Start. Total

Harmonic Distortion < 10% No. of Ballast

1, 2 or 3

EB2 =T12 Electronic Rapid Start.

No. of Ballast 1 or 2

DLS=Digital Lighting System Dimming

(For complete details on generic or to specify manufacturer’s ballast see pg. 469)

COOPER LIGHTING

NOTES: (1)An EQ Grid Clip is recommended for all 9/16" ceiling systems. (2)Standard off-center ballast compartment on 3-lamp fixtures. (3)Products also available in non- US voltages and frequencies for international markets. (4) Not available when specifying emergencies, voltage must be specific.

For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information.