MD42FLW_FLB 825-0132.qxd:MD Series 325-1432.qxd 5/28/08 8:27 PM Page 5

attempt to use with other electrical fixtures! These connectors are designed to withstand the temperature and voltage requirements of this Cooper Lighting, LLC product only.

Step 2: Attach your ground supply wire to the fixture using the green ground screw.

Step 3: Connect black fixture wire to black supply wire (hot). Secure with wire nut (not included).

Step 4: Connect white fixture wire to white supply wire (neutral). Secure with wire nut (not included).

Step 5: Be careful to connect the wires correctly. Make sure no bare strands of wire extend from the wire nut or other approved wire connectors (not included).

Attaching access cover and lens

Step 1: If your fixture is to be mounted to a standard lampholder mounting plate, remove the U-shaped knockout on the back of the cover (Fig. 6) using a hammer and screwdriver.

Step 2: Attach the access cover (C) to the light fixture using

 

 

Fig. 6

access cover mounting screws (D) provided (Fig. 7).

 

 

 

 

Note: Make sure all wiring is inside of the fixture arm before

 

 

 

 

 

 

 

 

the access cover is secured.

 

 

 

 

Step 3: Attach the lens to the housing by carefully lining up

 

 

 

 

the slots on the lens to the tabs on the housing.

 

 

Fig. 7

Carefully insert the slots over the tabs, and twist the

 

 

 

 

 

 

 

 

lens clockwise until it locks into place (Fig. 8).

 

 

 

 

Locate the lens lock screw (F) in the hardware bag.

 

 

 

 

Place this screw in the screw hole located at the top

 

 

 

 

front of the fixture (Fig. 9). Tighten the screw to hold

 

 

 

 

the lens in place.

 

 

 

 

 

 

Fig. 8

Installing the bulb

Step 1: Screw the bulb (J) securely into socket.

Step 2: Back the bulb out one or two turns, then screw bulb back to insure proper position in socket.

Operating your fixture

 

Fig. 9

Step 1: Turn on the power at the main fuse/breaker box.

 

Step 2: Turn power on to the fixture. Your fixture should come on for 1 – 4 minutes, then go off during daylight installation.

Step 3: To test your fixture, cover the light sensor for 1 – 3 minutes. Your fixture should come on. Uncover the sensor, and your fixture should turn off in 1 – 4 minutes.

Installing the optional light shield/reflector

Note: Sometimes fixtures are installed in locations that receive too much reflected light. The photo sensor may have trouble telling the difference between daylight

Call for customer service and/or missing or damaged parts (800-334-6871)