Metalux • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801 10/06/2008 12:19:15 PM
Specifications and Dimensions subject to change without notice.
ADF070947
PHOTOMETRICS
MB
Coefficients of Utilization
Effective floor cavity reflectance 20%
rc 80% 70% 50% 30% 10% 0%
rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
RCR
0
1
2
3
4
5
6
7
8
9
10
Zonal Lumen Summary
Zone Lumens %Lamp %Fixture
0-30
0-40
0-60
0-90
0-180
||
Candela
Angle Along II 45° Across
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90

MB-132-NB/PLUS

(1) Electronic Ballast

(1) 32W T8 lamp

2850 lumens

Spacing criterion:

(II) 1.2 x mounting

height, () 1.0 x

mounting height

Efficiency 94.1%

Test Report:

10267

LER =FL74

Yearly Cost of 1000

lumens, 3000 hrs at

.08 KWH = $3.24

889 889 889
900 934 963
888 1002 1037
869 1008 921
843 904 803
809 803 687
767 687 613
719 589 628
665 535 653
605 535 645
540 534 607
470 504 560
396 454 457
316 384 343
235 272 324
154 223 280
78 174 190
19 89 98
2 11 14
112 112 112 112 109 109 109 109 105 105 105 100 100 100 96 96 96 94
101 97 92 88 99 94 90 87 90 87 84 87 84 81 83 81 79 77
92 84 77 71 89 82 76 70 78 73 69 75 71 67 72 69 65 63
84 73 65 59 81 72 64 58 69 62 57 66 61 56 64 59 55 53
76 65 56 50 74 63 55 49 61 54 49 59 53 48 57 51 47 45
70 58 49 43 68 57 48 42 55 47 42 53 46 41 51 45 41 39
65 52 43 37 63 51 43 37 49 42 37 48 41 36 46 40 36 34
60 47 39 33 58 46 38 33 45 38 32 44 37 32 42 36 32 30
56 43 35 29 55 42 35 29 41 34 29 40 34 29 39 33 29 27
52 40 32 26 51 39 32 26 38 31 26 37 31 26 36 30 26 24
49 37 29 24 48 36 29 24 35 28 24 34 28 24 33 28 24 22
722 25.3 26.9
1133 39.8 42.3
2013 70.6 75.0
2680 94.0 99.9
2682 94.1 100.0
Luminance Data
Average Average Average
Angle 0-Deg 45-Deg 90-Deg
in Deg cd/sm cd/sm cd/sm
45
55
65
75
85
4400 3449 4020
4171 3787 4021
3741 3587 3012
2869 2868 3293
894 1932 1829
Coefficients of Utilization
Effective floor cavity reflectance 20%
rc 80% 70% 50% 30% 10% 0%
rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
RCR
0
1
2
3
4
5
6
7
8
9
10
Zonal Lumen Summary
Zone Lumens %Lamp %Fixture
0-30
0-40
0-60
0-90
0-180
||
Candela
Angle Along II 45° Across
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90

MB-132FB

(1) Electronic Ballast

(1) 32W T8 lamp

2850 lumens

Spacing criterion:

(II) 1.2 x mounting

height, () 0.5 x

mounting height

Efficiency 96.8%

Test Report:

09363

LER =FL77

Yearly Cost of 1000

lumens, 3000 hrs at

.08 KWH = $3.11

2558 2558 2558
2548 2427 2312
2513 2075 1735
2460 1619 1245
2378 1240 915
2275 947 688
2147 732 549
2004 583 410
1845 455 355
1669 337 340
1477 286 297
1261 259 146
1047 189 5
824 60 0
589 0 0
373 0 0
170 0 0
27 0 0
0 0 0
115 115 115 115 113 113 113 113 108 108 108 103 103 103 99 99 99 97
108 105 102 99 106 103 100 98 99 97 95 95 94 92 92 91 89 88
101 96 91 87 99 94 89 86 91 87 84 88 85 82 85 82 80 78
95 87 81 76 93 86 80 76 83 78 75 81 77 73 78 75 72 70
88 79 73 68 86 78 72 67 76 71 66 74 69 66 72 68 65 63
82 72 65 60 80 71 65 60 69 64 59 68 63 59 66 62 58 56
77 66 59 54 75 65 59 54 64 58 53 62 57 53 61 56 53 51
72 61 54 49 70 60 53 49 59 53 48 57 52 48 56 51 48 46
67 56 49 44 66 55 48 44 54 48 43 53 47 43 52 47 43 41
62 51 44 39 61 50 44 39 49 43 39 48 43 39 47 42 39 37
58 47 40 36 57 46 40 35 46 40 35 45 39 35 44 39 35 34
1251 43.9 45.3
1758 61.7 63.7
2535 88.9 91.9
2759 96.8 100.0
2759 96.8 100.0
Luminance Data
Average Average Average
Angle 0-Deg 45-Deg 90-Deg
in Deg cd/sm cd/sm cd/sm
45
55
65
75
85
45619 3312 3499
39272 3074 1852
30937 935 0
18360 0 0
2025 0 0
Coefficients of Utilization
Effective floor cavity reflectance 20%
rc 80% 70% 50% 30% 10% 0%
rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
RCR
0
1
2
3
4
5
6
7
8
9
10
Zonal Lumen Summary
Zone Lumens %Lamp %Fixture
0-30
0-40
0-60
0-90
0-180
||
Candela
Angle Along II 45° Across
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90

MB-132-TB

(1) Electronic Ballast

(1) 32W T8 lamp

2850 lumens

Spacing criterion:

(II) 1.2 x mounting

height, () 0.7 x

mounting height

Efficiency 95.1%

Test Report:

10266

LER =FL76

Yearly Cost of 1000

lumens, 3000 hrs at

.08 KWH = $3.16

2427 2427 2427
2418 2349 2307
2386 2238 2269
2331 2223 2182
2253 2113 2067
2153 2015 1857
2034 1784 1559
1895 1616 1098
1738 1288 848
1563 897 548
1373 662 409
1169 416 192
955 275 11
734 90 2
517 4 2
317 2 2
156 1 1
45 1 1
0 0 0
113 113 113 113 111111111111 106 106 106 101101101 97 97 97 95
102 97 93 89 100 95 91 87 91 88 85 87 84 82 84 82 79 77
93 84 77 71 90 82 76 70 79 73 69 76 71 67 73 69 66 63
84 73 65 59 82 72 64 58 69 62 57 66 61 56 64 59 55 53
77 65 56 49 74 63 55 49 61 54 48 59 53 48 57 51 47 45
70 58 49 42 68 57 48 42 55 47 42 53 46 41 51 45 41 38
65 52 43 37 63 51 43 37 49 42 36 48 41 36 46 40 36 34
60 47 39 33 59 46 38 32 45 37 32 43 37 32 42 36 32 30
56 43 35 29 55 42 34 29 41 34 29 40 33 29 39 33 28 26
53 40 32 26 51 39 31 26 38 31 26 37 30 26 36 30 26 24
49 37 29 24 48 36 29 24 35 28 24 34 28 23 33 28 23 22
700 24.6 25.8
1104 38.7 40.7
2001 70.2 73.8
2708 95.0 99.9
2711 95.1 100.0
Luminance Data
Average Average Average
Angle 0-Deg 45-Deg 90-Deg
in Deg cd/sm cd/sm cd/sm
45
55
65
75
85
4932 3249 3861
4467 3652 3961
3746 3663 3356
2639 2784 3378
844 1990 1869