P D 6 - V 1 4 2

P H O T O M E T R I C S

Candlepower Distribution

 

Single Unit Foot-candles

 

Candlepower

 

Avg Luminance CD/SQ M

 

Downlight

Wall Washer

 

Efficiency = 35.6%

 

 

2’6” Distance from wall

 

Downlight

Degree Wall Washer

Deg.

Downlight

Wall Washer

 

 

 

 

 

 

 

 

 

(single fixture)

 

549

0

549

45

29019

39074

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

80°

 

 

 

 

 

 

 

 

 

 

55

22182

30555

 

 

120

 

 

 

 

DD

1'

2'

3'

4'

5'

6'

520

5

572

 

 

 

 

70°

 

 

65

7379

13577

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Test No. 12136

 

1

8

6

4

2

1

1

1

436

15

602

75

4338

8193

 

 

 

 

 

 

 

 

 

240

 

 

60°

PD6-V142E-6VWC

2

20

17

9

4

2

1

1

345

25

570

85

2862

3578

 

 

 

 

 

Lamp = 42W TTT

3

19

17

10

6

3

2

1

271

35

499

 

 

 

 

 

 

 

 

50°

 

 

 

 

 

 

 

 

 

 

4

14

14

9

6

3

2

1

189

45

443

 

 

 

 

 

360

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

10

10

7

5

3

2

2

127

55

281

 

 

 

 

 

 

 

 

40°

 

 

6

7

7

6

4

3

2

2

 

 

 

 

 

 

 

 

 

 

50

65

92

 

 

 

 

 

480

 

 

 

 

 

7

5

5

4

3

3

2

2

 

 

 

 

 

 

 

 

 

 

19

75

34

 

 

 

 

 

 

 

 

 

 

 

8

4

4

3

3

2

2

1

 

 

 

 

 

 

 

 

 

 

 

3

85

5

 

 

 

 

 

600

 

 

 

 

 

9

3

3

3

2

2

2

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30°

20°

10°

20°

30°

 

 

0

2

2

2

2

2

1

1

0

90

0

 

 

 

10°

 

 

 

 

 

Candlepower Distribution

 

 

Candelas

Cone of Light

 

 

 

Candela

 

 

 

 

 

 

 

 

 

 

Vertical

 

Distance to

 

 

 

Initial Nadir

 

 

Beam

 

 

 

Spacing Criteria = 1.1

 

 

 

CD

Illuminated Plane

 

 

Footcandles

 

 

Diameter

 

 

 

Efficiency = 57.7%

 

 

 

Angle

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

90

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Test No. H22342

250

 

 

85

0

5'6"

 

 

 

 

22

 

 

 

6'

 

 

 

 

 

75

1

 

 

 

 

 

 

 

 

 

 

PD6-V142E-6VC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

65

2

6'6"

 

 

 

 

16

 

 

 

7'

 

 

 

Lamp = 26W PLT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

55

18

8'0"

 

 

 

 

10

 

 

 

9'

 

 

 

Lumens = 1800

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

45

232

10'0"

 

 

 

 

6

 

 

 

11'

 

 

 

 

 

 

500

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

35

440

12'0"

 

 

 

 

5

 

 

 

13'

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

25

637

14'0"

 

 

 

 

4

 

 

 

15'6"

 

 

 

 

 

 

 

 

 

15

701

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Beam diameter is to 50% of maximum footcandles, rounded to the nearest half-foot.

 

 

 

 

 

 

750

 

 

5

685

Footcandle values are initial, apply appropriate light loss factors where necessary.

 

 

 

 

 

 

 

 

0

663

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Candlepower Distribution

Spacing Criteria = 1.1

 

 

 

Efficiency = 46.9%

 

 

 

 

 

 

 

Test No. H22330

 

250

 

PD6-V142E-6VC

 

 

 

Lamp = 32W PLT CFL

 

 

 

Lumens = 2400

 

 

 

 

 

 

 

 

 

 

500

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

750

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Candelas

Vertical

CD

Angle

 

 

 

90

0

85

1

75

4

65

14

55

62

45

264

35

476

25

619

15

686

5

694

0

685

 

 

Cone of Light

Distance to

Initial Nadir

Beam

Illuminated Plane

Footcandles

Diameter

5'6"

 

 

 

6'

23

6'6"

16

7'

8'0"

11

9'

10'0"

7

 

11'

12'0"

5

 

13'

14'0"

4

 

15'6"

Beam diameter is to 50% of maximum footcandles, rounded to the nearest half-foot. Footcandle values are initial, apply appropriate light loss factors where necessary.

Candlepower Distribution

 

Candelas

Cone of Light

 

 

 

 

Vertical

 

Distance to

Initial Nadir

Beam

Spacing Criteria = 1.1

 

CD

Illuminated Plane

Footcandles

Diameter

Efficiency = 46.1%

 

Angle

 

 

 

 

 

90

0

 

 

 

 

 

 

 

 

Test No. H22331

300

85

7

5'6"

24

6'

75

24

PD6-V142E-6VWB

 

6'6"

17

7'

 

65

30

Lamp = 32W PLT CFL

 

 

8'0"

11

9'

 

55

42

Lumens = 2400

 

 

45

204

10'0"

7

11'

 

600

 

35

429

12'0"

5

13'

 

 

25

631

14'0"

4

15'6"

 

 

15

754

Beam diameter is to 50% of maximum footcandles, rounded to the nearest half-foot.

 

 

5

756

Footcandle values are initial, apply appropriate light loss factors where necessary.

 

 

 

 

 

 

900

0

721

 

 

 

Candlepower Distribution

 

Candelas

Cone of Light

 

 

 

 

Vertical

 

Distance to

Initial Nadir

Beam

Spacing Criteria = 1.1

 

CD

Illuminated Plane

Footcandles

Diameter

 

 

Angle

 

 

 

 

Efficiency = 41.7%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

90

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Test No. H22332

300

85

0

 

5'6"

24

6'

75

4

PD6-V142E-6VBB

 

 

6'6"

17

7'

 

65

5

Lamp = 32W PLT CFL

 

 

 

8'0"

11

9'

 

 

55

18

Lumens = 2400

 

600

45

184

10'0"

7

11'

 

 

 

 

 

 

 

 

 

 

 

 

35

414

 

12'0"

5

13'

 

 

 

 

 

 

 

 

 

 

 

 

 

25

621

 

14'0"

4

15'6"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15

753

Beam diameter is to 50% of maximum footcandles, rounded to the nearest half-foot.

 

 

 

 

 

 

 

5

752

Footcandle values are initial, apply appropriate light loss factors where necessary.

 

 

 

 

 

 

900

0

711

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note: Specifications and Dimensions subject to change without notice.

Visit our website at www.cooperlighting.com

Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770 468.4801 ADV995023

10/11/2007

Page 2
Image 2
Cooper Lighting PD6-V142 manual O T O M E T R I C S, Candlepower Distribution Candelas Cone of Light

PD6-V142 specifications

Cooper Lighting’s PD6-V142 represents a significant advancement in the field of indoor and outdoor lighting solutions. This versatile fixture is designed to cater to a wide range of applications, from residential spaces to commercial environments, making it a popular choice among lighting designers and architects.

One of the standout features of the PD6-V142 is its energy efficiency. Equipped with LED technology, this lighting solution not only reduces power consumption but also boasts an extended lifespan compared to traditional lighting options. This results in lower operational costs and contributes to sustainability efforts as less frequent replacements reduce waste.

The fixture is designed with versatility in mind. Available in multiple wattages and color temperatures, users can customize the lighting to meet specific requirements. This flexibility makes the PD6-V142 suitable for various settings, whether illuminating a cozy living room, enhancing a retail display, or providing adequate light for outdoor spaces.

Another significant feature is the PD6-V142's advanced optical design. With its precision-engineered lenses, the fixture offers excellent light distribution, minimizing hotspots and ensuring uniform illumination. This characteristic is particularly beneficial in commercial applications where consistent lighting can impact safety and aesthetics.

Durability is a hallmark of the PD6-V142. Constructed with high-quality materials, including corrosion-resistant housings, this fixture is built to withstand the elements when used outdoors. Its robust design ensures longevity, even in harsh environments, making it an ideal choice for industrial settings.

The integration of smart technology further enhances the PD6-V142’s appeal. Compatible with modern control systems, users can easily adjust lighting levels, create scenic lighting scenarios, or synchronize with building management systems for automated control. This ability to adapt lighting to real-time needs enhances user experience and operational efficiency.

Safety is paramount, and the PD6-V142 is designed with this in mind. The fixture is compliant with rigorous safety standards, providing peace of mind for users. Additionally, its low heat generation reduces the risk of burns and fires, making it a safer alternative to traditional lighting sources.

In conclusion, the Cooper Lighting PD6-V142 stands out in the lighting market due to its energy efficiency, versatility, optical performance, durability, smart technology integration, and safety features. This fixture is an excellent choice for anyone looking to enhance their lighting environment while maintaining a commitment to sustainability and efficiency.