TM
INSTALLATION INSTRUCTIONS
IMPORTANT: Read carefully before installing fixture. Retain for future reference.
Epic/Wall Mounted
Fixtures
Sheet 4 of 4
10/18/05
WARNING: Risk of Electric Shock. Disconnect power at fuse or circuit breaker before installing or servicing.
Vertically lamped
1. | Loosen and remove ring retaining screws globe retaining |
| ring and globe. Components are not tethered. |
| See Figure 5. |
2. | Remove two screws on ballast cover followed by ballast |
| cover. See Figure 6. |
3. | Unplug optic |
4. | Unplug service |
5. | Loosen the two screws holding the power pack to the |
| fixture housing. See Figure 7. |
6. | Holding the power pack by the handle, rotate the power |
| pack until free and lower. |
7. | Holding replacement power pack by handle, raise onto |
| screw heads and rotate. |
8. | Tighten the two screws while holding power pack in |
| position. |
9. | Plug together the service |
10. | Plug together the optic |
Ballast Cover
Screws
Optic
Quick-
Disconnect
Fig. 7a
11. | Resecure the ballast cover with the two screws. |
12. | Reinstall ring retaining screws securing globe retaining ring |
| and globe. In the case of type 3 refractive glass globe, use |
| the mark on globe bottom for orientation. |
Fuse
Handle
Starter
Keyhole Slot
RemovalRectangular Washer
Thumbscrew
Fig. 6
Service
Fig. 7b
Screws
Power Pack Removal | Fig. 8 |
These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible contingency during installation, operation or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for user’s purpose, please contact your nearest representative.
Customer First Center • 1121 Hwy 74 South • Peachtree City, GA 30269