FIGURE 16. SYRUP LINE STRAIANER

1.Using chlor–tergent (Oakite Products, Inc.) or equivalent sanitizer and LUKEWARM water, mix 2–1/2 gallons (9.46 liters) of sanitizing solution in a bucket.

2.Disconnect syrup out quick disconnects, containing the syrup strainers, from all syrup tanks.

3.Activate all dispensing valves on Dispensers to relieve pressure from all syrup systems.

4.Loosen syrup strainer screen (see Figure 3–5) retainer, then pull syrup strainer and screen from syrup strainer housing.

5.Pull screen from screen retainer. Inspect screen for holes, restrictions, corrosion, and any other damage. Discard damaged screen and replace with a new one.

6.Place quick disconnect and syrup strainer housing in bucket containing sanitizing solution. Thoroughly wash quick disconnect and syrup strainer housing, screen retainer, and screen in sanitizing solution.

7.Thoroughly rinse quick disconnect and syrup strainer housing, screen retainer and screen with potable water.

8.Install screen in screen retainer, then screw screen retainer into water strainer housing. Tighten retainer only finger tight.

9.Repeat steps 4) through 8) to clean and sanitize remaining syrup strainers.

10. Sanitize all syrup systems as instructed.

11.Connect syrup out quick disconnects to all syrup tanks.

WATER FILTERS REPLACEMENT

Refer to Water Filtration System manual for water filters replacement instructions.

SANITIZING SYRUP SYSTEMS

The syrup systems should be sanitized every

90–days using Chlor–Tergent (Oakite Products, Inc.) or equivalent sanitizer. Refer to manual provided with the Post–Mix Dispenser for sanitizing instructions.

REPLENISHING CO2 SUPPLY

NOTE: When indicator on CO2 cylinder regulator assembly 1800–PSI (124.1 Bars) gauge is in shaded (‘‘Change CO2 Cylinder’’) portion of dial, CO2 cylinder is almost empty and should be changed.

1.Fully close (clockwise) CO2 cylinder valve.

2.Slowly loosen CO2 regulator assembly coupling nut allowing CO2 pressure to escape, then remove regulator assembly from empty CO2 cylinder.

3.Unfasten safety chain and remove empty CO2 cylinder.

WARNING: To avoid personal injury and/or property damage, always secure CO2 cylinder with safety chain to prevent if from falling over. Should the valve become acciden- tally damaged or broken off, CO2 cylinder can

cause serious personal injury.

4.Position CO2 cylinder and secure with safety chain.

5.Make sure gasket is in place inside CO2 regulator coupling nut, then install regulator on CO2 cylinder.

6.Open (counterclockwise) CO2 cylinder valve slightly to allow lines to slowly fill with gas, then open valve fully to back–seat valve. (Back–seating valve prevents leakage around valve shaft).

7.Check CO2 connections for leaks. Tighten loose connections.

REPLENISHING SYRUP SUPPLY

WARNING: To avoid personal injury or property damage, do not attempt to re- move syrup tank cover until CO2 pressure has

been released from tank.

28

0713

 

Page 29
Image 29
Cornelius 2232MS Sanitizing Syrup Systems, Replenishing CO2 Supply, Replenishing Syrup Supply, Been released from tank

2232MS specifications

The Cornelius 2232MS is an advanced beverage dispensing system that combines cutting-edge technology with user-friendly features, making it an ideal choice for various commercial settings, such as restaurants, bars, and convenience stores. This model stands out due to its impressive performance and innovative design, which cater to the diverse needs of beverage service.

One of the key features of the Cornelius 2232MS is its high-capacity dispensing capability. The system can accommodate a wide range of beverage types, including carbonated soft drinks, teas, and flavored syrups. This versatility allows businesses to offer a broader menu, appealing to a wider customer base. The dispensers are designed to handle multiple flavors simultaneously, ensuring that patrons can enjoy their favorite drinks without long wait times.

Technology plays a critical role in the operation of the Cornelius 2232MS. The system is equipped with an advanced touchless dispensing interface, which minimizes the risk of cross-contamination and promotes a hygienic environment. Users can easily select their preferred beverage with just a touch, making the experience both efficient and enjoyable. Additionally, the unit features programmable settings that allow operators to customize drink proportions and carbonic acid levels, ensuring consistent quality in every pour.

Another notable characteristic of the Cornelius 2232MS is its energy-efficient design. The system utilizes eco-friendly technology that reduces power consumption, making it an environmentally responsible option for businesses. This energy efficiency not only contributes to cost savings on utility bills but also aligns with modern sustainability goals.

Maintenance and serviceability are also prioritized in the design of the Cornelius 2232MS. The unit features easy-to-access components for cleaning and servicing, which minimizes downtime. Regular maintenance can be performed with minimal effort, ensuring that the system remains in optimal condition for prolonged use.

In conclusion, the Cornelius 2232MS stands out in the beverage dispensing market due to its versatility, cutting-edge technology, and energy efficiency. Its user-friendly interface and easy maintenance make it a practical choice for any business looking to elevate their beverage service. With the Cornelius 2232MS, operators can expect enhanced customer satisfaction and improved operational efficiency, solidifying its position as a leader in beverage dispensing solutions.