TROUBLESHOOTING

IMPORTANT: Only qualified personnel should service internal components or electrical wiring.

WARNING: If repairs are to be made to carbonated water system, disconnect electrical power to Cooling Unit, shut off plain water and CO2 supplies, and relieve the carbonated water system pressure before proceeding. If repairs are to be made to syrup system,

remove quick disconnects from applicable syrup tank, then relieve the system pressure before proceeding. If repairs are to be made to CO2 system, stop dispensing, shut off CO2 supply, then relieve the system pressure before proceeding.

If repairs are to be made to an existing Remote Condensing unit, disconnect the power to the condensing unit before proceeding

TROUBLESHOOTING OPTIONAL WATER PRESSURE BOOSTER SYSTEM

Trouble

 

Probable Cause

Remedy

WATER PUMP NOT

A.

Power cord unplugged from

A. Plug power cord into electrical

OPERATING

 

electrical outlet.

outlet.

 

B. Electrical circuit fuse blown or

B. Replace fuse or reset circuit

 

 

circuit breaker tripped.

breaker.

 

C.

Water pump motor inoperative

C. Have Service Technician replace

 

 

 

inoperative moto

 

D. Water pump pressure switch

D. Have Service Technician replace

 

 

inoperative.

inoperative pressure switch.

 

E.

Thermal overload switch

E. Have Service Technician replace

 

 

inoperative.

inoperative thermal overload

 

 

 

switch.

F.Plain water inlet pressure above 60–PSI (4.14 Bars).

F.Have Service Technician reset ‘‘CUT IN’’ pressure on pressure switch to 10–PSI (.68 Bars) above water inlet pressure.

WATER PUMP

A. Water tank is overcharged with

A. Evacuate all water from Beverage

‘‘SHORTCYCLES’’

air, CO2 or nitrogen gas.

Support System. Adjust pressure

 

 

to 40 ± 5–PSI (2.76 ± .34 Bars),

 

 

then reactivate system.

 

B. Check to see if check valve on

B. Disassemble and clean check

 

water pump outlet is leaking

valve. If valve is damaged,

 

water

replace.

 

C. Water tank shutoff valve is

C. Open water tank shutoff valve

 

closed

 

 

D. Water pump pressure switch is

D. Have Service Technician readjust

 

not correctly adjusted.

the pump pressure switch.

 

 

 

WATER PUMP ‘‘LONG

A.

Water tank is undercharged

CYCLES’’

 

with air, CO2, or nitrogen gas.

 

B.

Water tank gas bladder is

 

 

leaking.

A.Evacuate all water from Beverage

Support System. Adjust gas pressure to 40 ± 5 PSI, (2.76 ±

.34 Bars) then reactivate system.

B.Replace water tank, pressurize gas pressure to 40 ± 5–PSI (2.76

± .34 Bars), then reactivate.