Cornelius 2232MS Not Operate CON’T, AIR Compressor ‘SHORT, Dispensed Drinks have, ‘OFF’’ Taste

Models: 2232MS

1 47
Download 47 pages 14.46 Kb
Page 33
Image 33

Trouble

 

Probable Cause

 

Remedy

AIR COMPRESSOR DOES

E.

Air/CO2 changeover valve on

E.

Select desired valve position.

NOT OPERATE (CON’T)

 

CO2 panel set to CO2 position.

 

 

 

F.

Air compressor is inoperative.

F.

Replace air compressor.

 

 

 

 

 

AIR COMPRESSOR ‘SHORT

A.

Air compressor pressure

A.

Have Service Technician adjust

CYCLES’’

 

switch is not correctly

 

pressure switch.

 

 

adjusted.

 

 

B.Air tank contains water (condensation).

B.Drain water (condensation) from air tank by opening condensation drain tube valve. Close valve after draining tank. TO PREVENT WATER (CONDENSATION) FROM ENTERING SYSTEM, WATER MUST BE PURGED FROM AIR TANK ONCE A WEEK.

DISPENSED DRINKS HAVE

A. Air tank contains excessive

A. Drain water (condensation) from

‘OFF’’ TASTE

water (condensation).

air tank, then sanitize syrup

 

 

systems and replace

 

 

contaminated syrup supplies.

 

 

 

AIR COMPRESSOR‘‘LONG

A. Condensation drain tube valve

A. Place condensation drain valve in

CYCLES’’

on air tank is in ‘‘OPEN‘’

‘‘CLOSED’’ position.

 

position.

 

B.Pressure relief valve on air tank lid is open

B. Close air tank lid relief valve.

C.Air compressor air filter is clogged.

C.Replace air compressor air filter.

D.Air tank lid not properly installed.

D.Properly install lid on air tank.

 

E.

Leak in air system lines and/or

E.

Check for leak in air line from air

 

 

regulators.

 

compressor to air tank. Check line

 

 

 

 

from air tank to air/CO change

 

 

 

 

over valve. Check regulator and

 

 

 

 

lines to syrup tanks. Check line to

 

 

 

 

shake machine.

 

F.

Air compressor inoperative

F.

Replace air compressor.

 

 

 

 

 

WATER INLET PRESSURE

A.

Water inlet valve in

A.

Place water inlet shutoff valve in

GAUGE READS TOO LOW

 

‘‘CLOSED’’ position.

 

‘‘OPEN’’ position.

 

B.

Water pre–filter is clogged.

B.

Replace water pre–filter.

 

C.

Water pressure regulator is

C.

Readjust water pressure regulator

 

 

incorrectly adjusted.

 

to 75 ± 5 PSI (5.17 ± .34 Bars).

 

D.

Water pressure regulator

D.

Clean or replace water strainer

 

 

strainer is clogged.Water

 

filter after closing main water

 

 

pressure regulator strainer is

 

shutoff valve.

 

 

clogged.

 

 

 

E.

Water pressure regulator

E.

Call Service Technician.

 

 

inoperative.

 

 

 

 

 

 

 

WATER INLET PRESSURE

A.

Water pressure regulator is

A.

Readjust water pressure regulator

GAUGE READS TOO HIGH

 

incorrectly adjusted.

 

to 75–PSI (5.17 Bars)

 

B.

Water pressure regulator

B.

Call Service Technician.

 

 

inoperative.

 

 

 

NOTE: Refer to manual provided with carbonator for troubleshooting information.

 

 

32

 

0713

Page 33
Image 33
Cornelius 2232MS Not Operate CON’T, AIR Compressor ‘SHORT, Dispensed Drinks have, ‘OFF’’ Taste, Air Compressor‘‘Long