Trouble |
| Probable Cause |
| Remedy |
AIR COMPRESSOR DOES | E. | Air/CO2 changeover valve on | E. | Select desired valve position. |
NOT OPERATE (CON’T) |
| CO2 panel set to CO2 position. |
|
|
| F. | Air compressor is inoperative. | F. | Replace air compressor. |
|
|
|
|
|
AIR COMPRESSOR ‘SHORT | A. | Air compressor pressure | A. | Have Service Technician adjust |
CYCLES’’ |
| switch is not correctly |
| pressure switch. |
|
| adjusted. |
|
|
B.Air tank contains water (condensation).
B.Drain water (condensation) from air tank by opening condensation drain tube valve. Close valve after draining tank. TO PREVENT WATER (CONDENSATION) FROM ENTERING SYSTEM, WATER MUST BE PURGED FROM AIR TANK ONCE A WEEK.
DISPENSED DRINKS HAVE | A. Air tank contains excessive | A. Drain water (condensation) from |
‘OFF’’ TASTE | water (condensation). | air tank, then sanitize syrup |
|
| systems and replace |
|
| contaminated syrup supplies. |
|
|
|
AIR COMPRESSOR‘‘LONG | A. Condensation drain tube valve | A. Place condensation drain valve in |
CYCLES’’ | on air tank is in ‘‘OPEN‘’ | ‘‘CLOSED’’ position. |
| position. |
|
B.Pressure relief valve on air tank lid is open
B. Close air tank lid relief valve.
C.Air compressor air filter is clogged.
C.Replace air compressor air filter.
D.Air tank lid not properly installed.
D.Properly install lid on air tank.
| E. | Leak in air system lines and/or | E. | Check for leak in air line from air |
|
| regulators. |
| compressor to air tank. Check line |
|
|
|
| from air tank to air/CO change |
|
|
|
| over valve. Check regulator and |
|
|
|
| lines to syrup tanks. Check line to |
|
|
|
| shake machine. |
| F. | Air compressor inoperative | F. | Replace air compressor. |
|
|
|
|
|
WATER INLET PRESSURE | A. | Water inlet valve in | A. | Place water inlet shutoff valve in |
GAUGE READS TOO LOW |
| ‘‘CLOSED’’ position. |
| ‘‘OPEN’’ position. |
| B. | Water | B. | Replace water |
| C. | Water pressure regulator is | C. | Readjust water pressure regulator |
|
| incorrectly adjusted. |
| to 75 ± 5 PSI (5.17 ± .34 Bars). |
| D. | Water pressure regulator | D. | Clean or replace water strainer |
|
| strainer is clogged.Water |
| filter after closing main water |
|
| pressure regulator strainer is |
| shutoff valve. |
|
| clogged. |
|
|
| E. | Water pressure regulator | E. | Call Service Technician. |
|
| inoperative. |
|
|
|
|
|
|
|
WATER INLET PRESSURE | A. | Water pressure regulator is | A. | Readjust water pressure regulator |
GAUGE READS TOO HIGH |
| incorrectly adjusted. |
| to |
| B. | Water pressure regulator | B. | Call Service Technician. |
|
| inoperative. |
|
|
| ||||
NOTE: Refer to manual provided with carbonator for troubleshooting information. | ||||
|
| 32 |