Cornelius 2400 (R404A), 750 (R404A), SERIES 1100 (R22) service manual Trouble

Models: 2400 (R404A) SERIES 1100 (R22) 750 (R404A)

1 37
Download 37 pages 47.04 Kb
Page 29
Image 29
Manual background

Trouble

Probable Cause

Remedy

UNIT GOES OFF OR TRIPS CIRCUIT BREAKER. (CONT’D)

L.

Plugged expansion valve, or

L.

Check back pressure, replace

 

capillary tube causing low back

 

valve or capillary tube. Evacuate

 

pressure.

 

and re–charge system, replace

 

 

 

drier–strainer.

M.

Slight leak, causing low back

M.

Check back pressure, find gas

 

pressure.

 

leak, repair leak, evacuate

 

 

 

system, add drier and recharge.

N.

Loose hold–down assy.

N. Check and tighten or replace.

O.

Auger worn excessively on the

O.

Replace auger.

 

inside surfaces causing thicker

 

 

 

flaked ice to be made.

 

 

P.

Auger out of line causing

P.

Replace auger and evaporator

 

excessive wear on the lower

 

shell.

 

outside surface where it rubs

 

 

 

against evaporator shell liner

 

 

 

at the bottom.

 

 

Q.

Broken auger

Q.

Replace auger.

R.

Evaporator surfaces worn or

R.

Inspect and replace evaporator if

 

gouged, causing thicker ice to

 

necessary.

 

be made.

 

 

S.

Auger guide bushing worn

S.

Replace auger guide bushing

 

down.

 

(corkscrew type augers only).

T.

Loose gearmotor mounting

T.

Check and tighten.

 

place.

 

 

U.

Low water level in float tank

U.

Adjust float arm to maintain

 

reservoir.

 

correct water level.

V.

Worn thrust washer.

V.

Replace.

W.

Gearmotor Delay Thermostat

W.

Check operation and / or replace.

 

does not keep gearmotor

 

 

 

running after Bin Thermostat

 

 

 

shuts down.

 

 

166240009

26

Page 29
Image 29
Cornelius 2400 (R404A), 750 (R404A), SERIES 1100 (R22) service manual Trouble