IDC Operator’s Manual

START-UP AND OPERATING INSTRUCTIONS

ICE DRINK DISPENSER

The ice drink dispenser shall be installed by qualified personnel following instruction given in the Installation manual part number 621057403INS. Fill the hopper with ice. Dispense several large cups of ice (approximately 20 to 30 seconds total dispensing time) to allow ice to fill the cold plate cabinet. Add ice to the hopper as necessary to refill, then replace the lid. Allow 10 to 15 minutes for the cold plate to cool down. Repeat this procedure whenever the dispenser has run out of ice. Start up the beverage system and adjust faucets to the proper brix. Contact your local syrup distributor for complete information on the beverage system.

In normal operation, pushing the ice dispenser mechanism will cause ice to flow from the ice chute. Ice flow will continue until the dispenser mechanism is released. Dispensing of any faucet will provide beverage of the appropriate flavor.

CAUTION: Use caution to avoid spilling ice when filling dispenser. Clean up immediately any spilled ice from filling or operating the unit. To prevent contamination of ice, the lid must be installed on the unit at all times.

If the dispenser fails to dispense ice or beverage, refer to the troubleshooting section in the Installation Manual part number 621057403INS.

CLEANING INSTRUCTIONS

WARNING: Disconnect Power Before Cleaning. Do not use metal scrapers, sharp objects or abrasives on the ice storage hopper, top cover and the agitator disk, as damage may result. Do not use solvents or other cleaning agents, as they may attack the plastic material.

Soap solution – Use a mixture of mild detergent and warm (100oF) potable water.

Sanitizing solution – Dissolve 2 packets (4 oz.) Stera Sheen Green Label into 2 gallons of warm (80- 100oF) water to ensure 200 ppm of available chlorine.

DISPENSER

Cleaning Exterior Surfaces

Important: Perform the following daily.

1.Remove cup rest from drip tray.

2.Wash the drip tray with soap solution. Rinse drip tray with clean water and allow solution to run down the drain.

3.Wash cup rest with soap solution and rinse in clean water. Install the cup rest in the drip tray.

4.Clean all exterior surfaces of Unit with soap solution, then rinse with clean water.

Publication Number: 621057403OPR

- 2 -

© 2005-2006, IMI Cornelius Inc.

Page 6
Image 6
Cornelius IDC 2XX manual START-UP and Operating Instructions, Cleaning Instructions, Cleaning Exterior Surfaces, Dispenser