Cornelius SID650A/80-BC manual Switch?, Full?, Thermostat, Is Low, Water, Level Normal, In Evap.?

Models: SID650A/80 SID650W/80 SID650W/80-BC SID650W/80-B SID650A/80-B SID650A/80-BC

1 40
Download 40 pages 36.95 Kb
Page 24
Image 24
SWITCH?

 

 

 

2.A ICE MAKER PROBLEM

 

YES

IS

RUN

RUN/STOP

STOP

 

HOPPER

 

SWITCH?

 

 

FULL?

 

 

 

 

NO

 

 

 

PUT SWITCH IN RUN POSITION.

NORMAL SHUTOFF ON

BIN THERMOSTAT.

1.CHECK THERMOSTAT ADJUST- MENT.

2.REPLACE BIN THERMOSTAT.

IS BIN

NO

THERMOSTAT

 

OPEN?

 

 

YES

 

IS

 

 

 

IS LOW-

 

 

IS HIGH-

YES

WATER

YES

NO

PRESSURE

PRESSURE

 

LEVEL NORMAL

 

 

 

 

 

 

 

 

SWITCH

 

IN EVAP.?

 

 

 

SWITCH

 

 

 

 

 

 

OPEN?

 

 

OPEN?

 

 

 

 

 

 

 

 

NO

 

 

 

 

NO

 

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CHECK FOR LOOSE CONNECTION

 

 

 

 

 

 

 

 

 

 

OR BROKEN WIRE.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.CHECK THAT WATER SUPPLY IS OPEN.

2.CHECK WATER SUPPLY FILTER.

3.CHECK FOR PLUGGED WATER FLOAT VALVE.

4.CHECK ADJUSTMENT OF TIMER CAM #4. (WATER DUMP)

5.CHECK TIMER SWITCH #4.

6.CHECK IF WATER DUMP VALVE IS STUCK OPEN.

1.CHECK FOR REFRIGERANT

UNDER-CHARGE.

2.CHECK TXV VALVE.

AIR-COOLED UNITS

1.CHECK FOR RESTRICTED AIR FLOW AT TOP OR REAR OF UNIT.

2.CHECK FOR HOT AIR RECIRCULATING TO TOP INLET. ELIMINATE BY BAFFLING.

3.CHECK FOR DIRTY INLET AIR FILTER.

4.CHECK FOR DIRTY AIR-COOLED CONDENSER.

5.CHECK CONDENSER FAN MOTOR.

6.CHECK FOR REFRIGERANT OVER-CHARGE.

WATER-COOLED UNITS

1.CHECK WATER SUPPLY TO CONDENSER.

2.CHECK FOR FAULTY WATER REGULATOR VALVE.

3.CHECK FOR REFRIGERANT OVER-CHARGE.

4.CHECK FOR FOULED CONDENSER.

21

91704

Page 24
Image 24
Cornelius SID650A/80-BC, SID650W/80-BC manual Switch?, Full?, Thermostat, Is Low, Water, Level Normal, In Evap.?