STEP 9 – ELECTRICAL SYSTEM

STEP 9 – ELECTRICAL SYSTEM

Country Flame’s Smart Fireplace Furnace comes standard with two blowers each rated to move 525 cubic feet of room air per minute. The blower system includes all necessary parts, except some additional wire, required for a local certified electrician to install the blowers, speed controls, and the thermostat. The fireplace’s electrical system SHOULD BE tested before final brickwork is completed. If electrical testing is not done, access to installed

wiring may be limited or worse, not repairable without costly removal of brickwork. Request that the local electrician make sure all blowers, air discharge snap disc, and rheostats are properly working before completing the brickwork.

FIGURE 12: THERMAL SNAP DISK LOCATION

FIGURE 12 shows the location of the thermal snap disk on the right side behind the front grille. Service to this component should only be accomplished by a qualified technician. This snap disk comes pre-wired from the factory. Once connected to the main power circuit, this snap disk will automatically turn the blower system on and off as the Smart Fireplace Furnace reaches either the appropriate hot or cold temperature.

FIGURE 13: ELECTRICAL JUNCTION BOX

FIGURE 13 shows the location of the electrical junction box cover. A certified electrician should remove the cover of this junction box to connect the Smart Fireplace Furnace’s blower system to the household electrical grid and the supplied thermostat with proper temperature rated romex wire. WARNING: Failure to properly wire in the blower system can lead to shock hazard, a malfunctioning blower system, or could create a fire hazard. Contact a certified electrician to ensure proper installation of the Smart Fireplace Furnace blower system. NOTE: All wiring should be completed before masonry work is complete.