Water Filtration System Performance Data Sheet
Brand: Mach | Model: |
This system has been tested and certified by the Water Quality Association according to NSF/ANSI 42, 53, and 58 for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42, 53, and 58.
| Max. Allowable | Average | Average | Minimum | Average |
Substance | Concentration | Influent | Effluent | Percent | Percent |
| (mg/L) | (mg/L) | (mg/L) | Reduction (%) | Reduction (%) |
Arsenic (Pentavalant) | 0.010 | 0.05 | 0.006 | 79.1 | 87.7 |
Barium | 2.0 | 10 | 1.4 | 83.5 | 86.6 |
Radium 226/228 | 5pCi/L | 25pCi/L | 5pCi/L | N/A | N/A |
Cadmium | 0.005 | 0.031 | 0.002 | 89.0 | 92.7 |
Chromium (Hexavalent) | 0.1 | 0.358 | 0.023 | 93.8 | 95.1 |
Chromium (Trivalent) | 0.1 | 0.367 | 0.028 | 93.8 | 95.7 |
Lead | 0.010 | 0.153 | 0.005 | 93.6 | 95.1 |
Nitrate/Nitrite | 10 | 29.6 | 4.8 | 78.5 | 83.7 |
Selenium | 0.05 | 0.117 | 0.003 | 96.0 | 97.8 |
TDS | <187.5 | 741.5 | 27.7 | 95.7 | 96.3 |
Aesthetic Chlorine |
|
|
|
|
|
INNOSENSE | ≥ 50% | 2.07 | 0.56 | 54.53 | 72.8 |
POST CARBON | ≥ 50% | 1.96 | 0.53 | 55.0 | 72.8 |
VOC* |
|
|
|
|
|
INNOSENSE | ≥ 95% reduction | 0.32 | 0.0077 | 95.70 | 97.6 |
POST CARBON | ≥ 95% reduction | 0.298 | 0.005 | 96.0 | 98.3 |
While testing was performed under laboratory conditions, actual performance may vary.
General Operating Information:
| INNO SENSE FILTER | 229 gallons (for VOC) | |
| 6,103 gallons (for Aesthetic Chlorine) | ||
Rated Capacity |
| ||
212 gallons (for VOC) | |||
| |||
| 1,179 gallons (for Aesthetic Chlorine) | ||
|
| ||
10 ~ 120 psi (0.7 ~ 8.4 kgf/cm2) | |||
41 ~ 95 ºF (5 ~ 35 ºC) | |||
Rated Service Flow | 0.07 GPM (for VOC) | ||
0.5 GPM (for Aesthetic Chlorine) | |||
|
| ||
Daily Water Production Rate | 82.3 GPD | ||
Product Efficiency Rating | 39.2 % | ||
Electrical Requirements: | 120 Vac / 60Hz |
•Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.
•Refer to the owners manual for specific installation instructions, manufacturer’s limited warranty, user responsibility, and parts and service availability.
•The influent water to the system shall include the following characteristics: o No organic solvents
o Chlorine: < 2 ppm
o pH: 7 - 8
o Temperature: 41 ~ 95 ºF (5 ~ 35 ºC)
o Iron: < 2 ppm
o Turbidity: < 1 NTU
o Hardness: < 1000 mg/L
R Others RFLOW DIAGWTE R RFOMANCEPDATAAM /SHEET
P RCH -03A