Coway CHP-03AL Water Treatment Device, Certificate Number, 08, Trademark/Model Designation

Models: CHP-03AL CHP-03AU CHP-03AR

1 42
Download 42 pages 44.6 Kb
Page 33
Image 33
Water Treatment Device

 

State of California

 

Department of Public Health

 

Water Treatment Device

 

Certificate Number

 

08 - 1867

 

Date Issued: June 24, 2008

 

 

 

 

Trademark/Model Designation

Replacement Element(s)

Mach CHP-03AR

WJNF11 Neo-Sense Filter

 

WJMF11-50 RO Membrane Filter

 

WJCF11-POST Post-carbon Filter

 

WJFF7 Fine Filter

 

WJCC-02 Ceramic Filter

Manufacturer: Woongjin Coway Co LTD

 

The water treatment device(s) listed on this certificate have met the testing requirements pursuant to Section

116830 of the Health and Safety Code for the following health related contaminants:

Microbiological Contaminants and Turbidity

Inorganic/Radiological Contaminants

None

Arsenic (Pentavalent)1

 

Barium

 

Cadmium

 

Chromium (Hexavalent)

 

Chromium (Trivalent)

 

Lead

 

Nitrate/Nitrite2

 

Radium 226/228

 

Selenium

Organic Contaminants

VOCs

Alachlor

Endrin

Simazine

Atrazine

Ethylbenzene

Styrene

Benzene

EDB

1,1,2,2-Tetrachloroethane

Carbofuran

Haloacetonitriles (HAN)

Tetrachloroethylene

Carbon Tetrachloride

Bromochloroacetonitrile

Toluene

Chlorobenzene

Dibromoacetonitrile

2,4,5-TP (Silvex)

Chloropicrin

Dichloroacetonitrile

Tribromoacetic Acid

2,4-D

Trichloroacetonitrile

1,2,4-Trichlorobenzene

DBCP

Haloketones (HK)

1,1,1-Trichloroethane

o-Dichlorobenzene

1,1-Dichloro-2-Propanone

1,1,2-Trichloroethane

p-Dichlorobenzene

1,1,1-Trichloro-2-Propanone

Trichloroethylene

1,2-Dichloroethane

Heptachlor

Trihalomethanes (THMs)

1,1-Dichloroethylene

Heptachlor Epoxide

Bromodichloromethane

cis-1,2-Dichloroethylene

Hexachlorobutadiene

Bromoform

trans-1,2-Dichloroethylene

Hexachlorocyclopentadiene

Chloroform

1,2-Dichloropropane

Lindane

Chlorodibromomethane

cis-1,3-Dichloropropylene

Methoxychlor

Xylenes

Dinoseb

Pentachlorophenol

 

Rated Service Capacity: 229 gal

 

Rated Service Flow: 0..07 gpm

Do not use with water that is microbiologically unsafe or of unknown quality, without adequate disinfection before or after the system..

1Claims for arsenic reduction shall only be made on water supplies maintaining detectable residual free chlorine at the reverse osmosis (RO) system inlet. Water systems using an in-line chlorinator should provide a minimum of 1minute chlorine contact time before the RO system.

2This system is acceptable for treatment of influent concentrations of no more than 27 mg/L nitrate and 3 mg/L nitrite in combination measured as N and is certified for nitrate/nitrite reduction only for water supplies with a pressure of 280 kPa (40 psig) or greater. A sampling and analysis test kit for nitrate is provided for checking the performance of this system.

Frequent analysis is encouraged.

Others R RFOMANCEPDATA SHEET

P RCH -03A

32

Page 33
Image 33
Coway CHP-03AL, CHP-03AR, CHP-03AU Water Treatment Device, Certificate Number, 08, Others R RFOMANCEPDATA SHEET P |RCH -03A