Coway CHP-03AR Model: CHP-03AL, Water Filtration System Performance Data Sheet, Brand: Mach

Models: CHP-03AL CHP-03AU CHP-03AR

1 42
Download 42 pages 44.6 Kb
Page 34
Image 34
Model: CHP-03AL

Water Filtration System Performance Data Sheet

Brand: Mach

Model: CHP-03AL

This system has been tested and certified by the Water Quality Association according to NSF/ANSI 42, 53, and 58 for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42, 53, and 58.

 

Max. Allowable

Average

Average

Minimum

Average

Substance

Concentration

Influent

Effluent

Percent

Percent

 

(mg/L)

(mg/L)

(mg/L)

Reduction (%)

Reduction (%)

Arsenic (Pentavalant)

0.010

0.05

0.006

79.1

87.7

Barium

2.0

10

1.4

83.5

86.6

Radium 226/228

5pCi/L

25pCi/L

5pCi/L

N/A

N/A

Cadmium

0.005

0.031

0.002

89.0

92.7

Chromium (Hexavalent)

0.1

0.358

0.023

93.8

95.1

Chromium (Trivalent)

0.1

0.367

0.028

93.8

95.7

Lead

0.010

0.153

0.005

93.6

95.1

Nitrate/Nitrite

10

29.6

4.8

78.5

83.7

Selenium

0.05

0.117

0.003

96.0

97.8

TDS

<187.5

741.5

57.8

91.5

92.2

Aesthetic Chlorine

 

 

 

 

 

INNOSENSE

≥ 50%

2.07

0.56

54.53

72.8

POST CARBON

≥ 50%

1.96

0.53

55.0

72.8

VOC*

 

 

 

 

 

INNOSENSE

≥ 95% reduction

0.32

0.0077

95.70

97.6

POST CARBON

≥ 95% reduction

0.298

0.005

96.0

98.3

While testing was performed under laboratory conditions, actual performance may vary.

General Operating Information:

 

INNO SENSE FILTER

229 gallons (for VOC)

 

6,103 gallons (for Aesthetic Chlorine)

Rated Capacity

 

POST-CARBON FILTER

212 gallons (for VOC)

 

 

1,179 gallons (for Aesthetic Chlorine)

 

 

Min-Max operating pressure:

20 ~ 120 psi (1.4 ~ 8.4 kgf/cm2)

Min-Max feed water temperature:

41 ~ 95 ºF (5 ~ 35 ºC)

Rated Service Flow

0.07 GPM (for VOC)

0.5 GPM (for Aesthetic Chlorine)

 

 

Daily Water Production Rate

43.7 GPD

Product Efficiency Rating

29.5 %

Electrical Requirements:

120 Vac / 60Hz

• Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.

• Refer to the owners manual for specific installation instructions, manufacturer’s limited warranty, user responsibility, and parts and service availability.

• The influent water to the system shall include the following characteristics:

 

o

No organic solvents

 

o Chlorine: < 2 ppm

 

o

pH: 7 - 8

 

o Temperature: 41 ~ 95 ºF (5 ~ 35 ºC)

 

o Iron: < 2 ppm

33

o Turbidity: < 1 NTU

o

Hardness: < 1000 mg/L

Page 34
Image 34
Coway CHP-03AR Model: CHP-03AL, Water Filtration System Performance Data Sheet, Brand: Mach, General Operating Information