C.F.MREQUIREMENTSFORTOOLS.

Machine

 

 

Minimum C.F._,_.Required

Minimum Duct Diameter

Band Saw (12 to 16qnch)

350

C,F,M,

4qnch

BeWDbc

Sander

 

450

C,F,M,

5qnch

DrHUPress

 

350

-

400

C,RM,

4qnch

Drum Sander (12 to 24qnch)

550

-

700

C,RM,

5qnch

Fbor Sweep

 

350

-

400

C,RM,

4 to 5qnch

Jointer

(up to 8qnch)

350

-

400

C,RM,

4 to 5qnch

Jointer

(over 8qnch)

450

-

550

C,RM,

5qnch

RadiaUArm Saw

 

450

-

600

C,RM,

5qnch

Miter Saw

 

 

450

-

600

C,RM,

5qnch

Router

TaMe

 

200

C,F,M,

3qnch

Scroll

Saw

 

200

C,F,M,

3qnch

Spindb

Sander

 

400

C,F,M,

4qnch

TaMe Saw (lOqnch)

350

C,F,M,

4qnch

Thickness

Haner

(10 to 15qnch)

400

C,F,M,

4qnch

Thickness

Planer

(16 to 20qnch)

600

-

800

C,RM,

5 to 6qnch

STATIC PRESSURE FIEQUJF{EMENTS FOR A DUST COLLECTION SYSTEM

Using STEPS 1 thru 4 and the "Static Pressure Requirement Chart" you can determine the static pressure required for your Dust Collector,

Step #1: Multiply the number of feet of Hose/Pipe times the appropriate inches rating,

Exampie; 40 feet of 4-inch diameter ribbed tubing x ,11 = 4.4 Total

Step #2: Multiply the fittings times the ratings and add them together,

Examp/e:Tw, o 90-degree Elbows (using 4qnch diameter Hose) = ,84 PLUS two 90-degree T-fittings = ,98 TotaJ = 1.82

Step #3: Add 2.5 for the Machine Hook-up and "Dirty Bag" factors (1,5 for Hook-ups + 1,0 for Dirty Bag),

Step #4: Total the above three calculations, This total should not exceed the maximum static

pressure for your Dust Collector,

Exaf_pie/4,4 (Total Step #1) x 1,82 (Total Step #2) + 2,5 (Total Step #3) = 8.72

For this example a Dust Collector with a Static Pressure rating of over 8.72 or higher is required. See Product Specifications on page 2 for your dust collector maximum static pressure.

NOTE: To determine if you have met the Static Pressure Requirement when using a Dust Collection System, identify the branch of the system with the highest static pressure requirement first, If you run your Dust Collection System with more than one blast gate open, add the static pressure from all branches that are open to determine the total static pressure requirements,

Static Pressure

Requirement

Chart

 

 

 

 

 

Size of Hose

Hose/Pipe

Ribbed Tubing

90-degree

90-degree

45-degree

Machine

"Dirty Bag"

 

Rigid Pipe

(per foot)

Elbow

Elbow

Tofitting

Hook-Up

Adjustment

 

(per foot}

 

 

 

 

 

 

 

3

.10

 

.15

.50

.60

.25

1.50

1.0

4

.07

 

.11

.42

.49

.21

1.50

1.0

5

.055

 

.08

.49

.55

.25

1.50

1.0

16

Page 16
Image 16
Craftsman 152.213351 Mrequirementsfortools, Static Pressure Fiequjfements for a Dust Collection System