Make certain pump is mounted and aligned properly
Use a flexible "spider" type coupling between engine and pump drive shafts
Keep hoses clear and unblocked Bleed air out of hoses before operating
Flush and clean hydraulic system before start- up after any malfunction or servicing
Use "pipe dope" on all hydraulic fittings
Allow time for
These accessories were available when the log splitter was purchased. These are also available at most Sears retail outlets, catalog and service centers. Most Sears stores can order repair parts for you when you provide the model number of your log splitter.
•Split wood with the grain (lengthwise) only
Never:
•Use when fluid is below 20+F, or above 150° F.
•Use a solid engine/pump coupling Force pump when mounting
•Operate through relief valve for several seconds Attempt to adjust unloading or relief valve settings without pressure gauges
•Operate with air in hydraulic system Use Teflon tape on hydraulic fittings
•Attempt to cut wood across the grain.
Tailight Kit