MAINTENANCE AND REPAIR INSTRUCTIONS

WARNING: Never use metal-reinforced line, wire, chain, or rope. These can break off and become dangerous projectiles.

WARNING: Always use the correct line length when installing trimming line on the unit.

INSTALLING FIXED LINE

Always use yellow Hassle Free IV™ XTRA QUIET Spiral Line. Lines other than this one may make the motor overheat or fail.

To install the trimming line:

1. Insert each end of the replacement line into the holes on either side of retention hook (Fig. 12).

2. Push the ends through until they stick out of the sides of the head (Fig. 13).

3. Pull the ends through making sure

Fig. 12

 

that the ends are of equal length

 

and the middle of the line is

 

centered between the insertion

 

holes (Fig. 14).

 

4. If the ends are not of equal length, push the longer end back through the head part way and pull the shorter end to compensate. Repeat until both ends are the same length.

Fig. 13

CLEANING

WARNING: To avoid serious personal injury, always turn your unit off and unplug it before you clean or service it.

Switch off the unit and disconnect it from the power source. Use a small brush to clean off the outside of the unit. Do not use strong detergents. Household cleaners that contain aromatic oils such as pine and lemon, and solvents such as kerosene, can damage plastic housing or handle. Wipe off any moisture with a soft cloth. Also keep the air vents free of obstructions.

INSPECT EXTENSION CORDS

Inspect all extension cords. Look closely for deterioration, cuts or cracks in the insulation. Inspect the connectors for damage. Replace a damaged or defective cord.

STORAGE

Allow the unit to cool before storing.

Lock the unit to prevent unauthorized use or damage.

Store the unit in a dry, well-ventilated area.

Store the unit out of the reach of children.

SERVICING DOUBLE INSULATED UNITS

This unit is double-insulated. In a double-insulated unit, two systems of insulation are provided instead of grounding. There is no grounding provided and no means of grounding should be added to this unit.

Extreme care and knowledge of the system is required when servicing a double-insulated unit. Service should be performed by qualified service personnel only. Replacement parts for a double- insulated unit must be identical to the parts they replace. Refer any repair to an authorized service dealer. A double-insulated unit is marked with the words “double insulation” or “double insulated.”

Fig. 14

5.Push the trimmer line behind the hook to secure it from coming loose while running

(Fig. 15).

Fig. 15