Craftsman 390.262653, 390.262454, 390.262553 owner manual ELECTRICAL Continued

Models: 390.262553

1 12
Download 12 pages 63.37 Kb
Page 6
Image 6
ELECTRICAL (Continued)

ELECTRICAL (Continued)

3.Disconnect power before servicing motor or pump. If the

disconnect switch is out of sight of pump, lock it open

and tag it to prevent unexpected power application.

4.Ground the pump permanently using a wire of the same

size as that specified in wiring chart (below). Make

ground connection to green grounding terminal under motor canopy marked GRD. or @.

5.Connect ground wire to a grounded lead in the service

panel or to a metal underground water pipe or well cas- ing at least 10 feet long. Do not connect to plastic pipe or insulated fittings.

6.Protect current carrying and grounding conductors from cuts, grease, heat, oil, and chemicals.

7.Connect current carrying conductors to terminals L1 and

L2 under motor canopy. When replacing motor, check

WIRING

Recommended

wiring diagram on motor nameplate against Figure 6. If the motor wiring diagram does not match the diagrams in Figure 6, follow the diagram on the motor.

IMPORTANT: 115/230 Volt single phase models are

shipped from factory with motor wired for 230 volts. If

power supply is 115 volts, remove motor canopy and re- connect motor as shown in Figure 6. Do not try to run motor as received on 115 volt current.

8. Motor has automatic internal thermal overload protec-

tion. If motor has stopped for unknown reasons, thermal

overload may restart it unexpectedly, which could cause

injury or property damage. Disconnect power before ser- vicing motor.

9.If this procedure or the wiring diagrams are confusing, consult a licensed electrician.

CHART

Wire and Fuse Sizes

DISTANCE IN FEET FROM MOTOR TO METER

 

 

 

 

Branch

 

0 I

51'

101'

201'

301'

401'

 

 

 

 

 

 

 

 

 

Max.

Fuse*

Min.

TO

TO

TO

TO

TO

TO

Pump

 

 

Load

Rating*

Wire

50'

100'

200'

300'

400'

500'

Model

HP

Volt

Amps

Amps

Size

 

 

WIRE SIZE

 

 

390.262454

1

115

14.2

20

12

12

12

8

6

6

4

230

7.5

15

14

14

14

14

14

12

10

 

 

390,262553

1-1/2

115

10.2

25

10

10

10

8

6

4

4

15

14

14

14

14

12

10

10

 

 

230

9.6

390.262653

2

230

12.0

15

14

14

14

14

12

10

10

*Dual element or Fusetmn time delay fuses recommended for all motor circuits.

6

Page 6
Image 6
Craftsman 390.262653, 390.262454, 390.262553 owner manual ELECTRICAL Continued