GENERAL RECOMMENDATIONS
The warranty on this unit does not cover items that have been subjected to oper- ator abuse or negligence. To receive full value from the warranty, the operator must maintain unit as instructed in this
manual. Various adjustments will need to be made periodically to properly maintain your unit.
BEFORE EACH USE
CHECK FOR LOOSE
FASTENERS AND PARTS
•Inlet Cover
•Blower Tube
•Vacuum Tubes
•Collection Bag
CHECK FOR DAMAGED OR
WORN PARTS
Contact Sears Service Center for re- placement of damaged or worn parts.
•ON/OFFSwitch - Ensure switch func- tions properly by moving the switch to
the OFF position. Make sure motor stops; then restart motor and continue.
•Inlet Cover - Discontinue use of unit if inlet cover fails to latch properly or if it is damaged in any way.
AFTER EACH USE
INSPECT AND CLEAN UNIT & LABELS
Stop unit and unplug extension cord.
•After each use, inspect complete unit for loose or damaged parts. Clean the unit using a damp cloth with a mild de- tergent.
•Wipe off unit with a clean dry cloth.
CLEAN COLLECTION BAG IMPORTANT: THE COLLECTION BAG MUST BE PROPERLY EMPTIED.
•You must properly empty and maintain the collection bag to avoid deteriora- tion and obstruction of air flow.
•Remove the collection bag from the unit and empty after each use. Do not store bag without emptying the bag of all contents (grass, leaves, etc.).
•Wash the bag once a year. Remove the bag from the blower and turn the bag inside out. Wash the bag with a water hose. Allow the bag to hang and dry completely before you reuse the bag.
HOW TO REMOVE AN OBJECT FROM THE AIR INTAKE
_II, WARNING: Stopthe unit and disconnect from the power source be- fore opening the inlet cover. The mo- tor must be stopped and the impeller blades no longer turning to avoid seri- ous injury from the rotating blades.
1.While holding the inlet cover open, remove the vacuum tubes. The in-
let cover must be held open through all remaining steps.
2.Carefully reach into the vacuum opening and clear out the air intake area. Clear all debris from impeller.
3.Inspect the impeller for cracks. If cracked or damaged, do not use the
unit. Have parts replaced by your Sears Service Center. Do not at-
tempt to replace them yourself. | ||
PARTS AVAILABLE | ||
Blower Tube | 530403765 | |
Elbow | Tube | 530403769 |
Upper | Vacuum | Tube/ |
Vacuum Assist | Handle & | |
Lower Vacuum Tube ... 530403989 | ||
Inlet Restrictor | ........ 530403791 | |
Collection Bag | ........ 530095599 | |
Gutter | Kit | |
Safety | Glasses | ........... |
Extension Cord | .....71-85709 |
10