StorageTek 6 manual Managing Over-useCleaning Cartridges

Models: 6

1 718
Download 718 pages 10.93 Kb
Page 70
Image 70
Managing Over-use Cleaning Cartridges

during tape transport cleaning. The default can be changed by using the MNTD EJctauto command.

Managing Over-use Cleaning Cartridges

If an operator is not available to empty a CAP, it may be desirable to retain over-use cleaning cartridges in the LSM for later removal.

The MNTD EJctauto command allows you to control processing of over-use cleaning cartridges.

Options for this command include:

ON

Use this option when operators are available to remove cleaning cartridges from a CAP during automated tape transport cleaning. ON is the initial value for the HSC. MSg Use this option when operators are available to respond to console messages during automated tape transport cleaning.

OFf

With this option, no operator intervention is required for automated tape transport cleaning.

When the HSC is searching for a cleaning cartridge to clean a tape transport, it skips all over-use cleaning cartridges that are detected in the ACS until it finds a compatible cleaning cartridge.

If no compatible cleaning cartridges are found in the ACS, the HSC prompts the operator to enter a cleaning cartridge or skip the clean process.

If compatible over-limit cleaning cartridges are found in the ACS, the HSC acts based on the MNTD EJctauto setting.

If MNTD EJctauto(ON) or (MSg) are set, an operator prompt is issued. The operator can reply to use one of these over-limit cleaning cartridges, enter a cleaning cartridge, or skip the clean process.

If MNTD EJctauto(OFf) is set, a compatible over-limit cleaning cartridge is automatically selected to clean the transport.

When the clean process is finished, the cleaning cartridge is dismounted from the tape transport. If the cleaning cartridge is over-use (over-limit or spent), the HSC acts based on the MNTD EJctauto setting.

If MNTD EJctauto(ON) is set, the cleaning cartridge is automatically ejected from the ACS.

If MNTD EJctauto(MSg) is set, an operator prompt is issued. The operator can reply to eject the cleaning cartridge from the ACS or keep the cleaning cartridge in the ACS.

If MNTD EJctauto(OFf) is set, the cleaning cartridge is automatically kept in the ACS.

40VM/HSC 6.0 System Programmer’s Guide

1st ed., 6/30/04 - 312579601

Page 70
Image 70
StorageTek 6 manual Managing Over-useCleaning Cartridges