StorageTek 6 JCL/Parameter File Requirements, Volume Report, SLSCNTL, SLSCNTL2, SLSSTBY, Slsprint

Models: 6

1 718
Download 718 pages 10.93 Kb
Page 363
Image 363
JCL/Parameter File Requirements

Volume Report

The totals are listed on a separate listing, on a new page from the Volume

Report Listing, the Control Card Listing, and the Volume Report Totals Listing.

An example displaying subpool information is shown in Figure 22 on page 344.

If subpools overlap (i.e., a volume belongs to more than one subpool) then the sum of the subpool totals may be greater than the total number of scratch volumes or the number of volumes in the library.

JCL/Parameter File Requirements

The following definitions apply to Volume Report utility JCL (SCP) and the parameter file (CMS):

SLSCNTL, SLSCNTL2, SLSSTBY

HSC control data set to be processed. SLSCNTL is required if Volume Report is run in a batch job with an active HSC. If the utility is run under CMS on another virtual machine, SLSCNTL, SLSSCRPL, and SLSVA must be included in the Volume Report parameter file.

SLSPRINT

output messages and report from the utility. A message is displayed detailing the data set names being used to produce the report.

SLSIN

input to the utility in the form of control statement card images.

SLSCDATA

statement required if VOLDATA and/or CDSDATA parameters are specified to request CDS data.

Note: The SLSCDATA statement can be specified only under CMS.

SLSSCRPL

points to a data set containing HSC PARMLIB statements. The SCRPOol scratch subpools and MNTD MAXclean values are defined in these control statements.

If this statement is omitted, the data set used by the active HSC on the host is accessed. If the HSC on the host is inactive, SLSSCRPL is required to produce a SUMMary(SUBpool) report.

Notes: The SLSSCRPL statement can be specified only under CMS.

SLSVA

statement that points to the data set containing the VOLATTR statements for the CDS being reported on.

If SLSVA or VOLATTRs are omitted, several different scenarios can occur depending on the HSC state. Table 18 describes these situations.

Chapter 4. Utility Functions 333

1st ed., 6/30/04 - 312579601