VOLATTR

Notes:

1.If MAXclean is not specified in the VOLATTR statement, the value or default of the MAXclean parameter in the MNTD operator command is used for all cleaning cartridge counts.

2.If MAXclean is specified, the MEDia setting must be Standard, DD3D, STK1U, or STK2W.

Example

The following example illustrates how to use VOLATTR statements to specify volume attributes for particular VOLSERs.

Set Volume Attributes

VOLATTR SERIAL(L*,AA9*) MEDIA(ECART)

VOLATTR SER(S*,PRD000­PRD499,BY*) MED(S) RECTECH(36)

VOLATTR SER(CLN200­CLN299) MED(DD3D) REC(HEL) MAXCLEAN(50)

VOLATTR SER(CLN300­CLN599) MED(S) REC(LONGI)

VOLATTR SER(*) REC(18)

Notes:

1.Ask your StorageTek CSE about recommended MAXCLEAN values for specific types of cleaning cartridges.

2.In the example above, the last VOLATTR statement specifies a user-defined default for all volumes that do not match any of the previous statements.

3.Note that recording technique is specified on all VOLATTR statements in the preceding examples, since the last statement specifies a RECtech(18), which is not the default (LONGI). If RECtech were omitted from the previous MED(S) VOLATTR statements, the REC(18) from the last VOLATTR statement would be used.