StorageTek 6 manual Initializing the HSC to the Base Service Level

Models: 6

1 718
Download 718 pages 10.93 Kb
Page 197
Image 197
Initializing the HSC to the Base Service Level

Initializing the HSC to the Base Service Level

HSC software can be started to the base service level by adding the BASE parameter on the /PARM statement of the startup SLKJCL, this includes specifying it on the ACS INIT or ACS SUBMIT commands. When using the CP AUTOLOG command, the BASE parameter must be specified on an existing /PARM statement in the startup SLKJCL. The BASE parameter can be used with other parameters on the /PARM statement.

When the BASE parameter is specified in the startup SLKJCL, the syntax to initialize the HSC to the base service level is the same as for initializing to the full service level.

When the BASE parameter is not specified in the startup SLKJCL, the commands used to initialize the HSC to the base service level must include a PARM=BASE parameter.

Syntax for Initializing HSC to Base Service Level

ACS INIT ( PARM=BASE - or -

ACS SUBMIT strtjclfn strtjclft strtjclfm libclass ( PARM=BASE

After initializing to this point, the SRVlev command can be used to bring the subsystem up to full function.

Chapter 3. HSC Control Statements and HSC Start Procedure 167

1st ed., 6/30/04 - 312579601

Page 197
Image 197
StorageTek 6 manual Initializing the HSC to the Base Service Level, Syntax for Initializing HSC to Base Service Level