StorageTek 6 manual 152-155

Models: 6

1 718
Download 718 pages 10.93 Kb
Page 637
Image 637
152-155

Table 67. Format for Total Motions and Temporary Error Counts (Continued)

Initiated and Temporary Error Motion Software Error Record

BYTE #

Description of Field

 

 

124-127

LSM 9 Temporary motion error counts (binary)

 

 

128-131

LSM 10 Robotic motions started (binary)

 

 

132-135

LSM 10 Temporary motion error counts (binary)

 

 

136-139

LSM 11 Robotic motions started (binary)

 

 

140-143

LSM 11 Temporary motion error counts (binary)

 

 

144-147

LSM 12 Robotic motions started (binary)

 

 

148-151

LSM 12 Temporary motion error counts (binary)

 

 

152-155

LSM 13 Robotic motions started (binary)

 

 

156-159

LSM 13 Temporary motion error counts (binary)

 

 

160-163

LSM 14 Robotic motions started (binary)

 

 

164-167

LSM 14 Temporary motion error counts (binary)

 

 

168-171

LSM 15 Robotic motions started (binary)

 

 

172-175

LSM 15 Temporary motion error counts (binary)

 

 

176-641

Reserved

 

 

642-643

Record type X’6506’

 

 

644-647

StorageTek identifier X’FEEDFACE’

 

 

648-651

Timestamp Table

 

 

The HSC also makes a log entry for each permanent error, codes and indicates whether or not the errors are considered permanent errors.

The record format used to log a hard fail to SYS1.LOGREC is shown in Table 68. This record is a valid ‘‘Motion Hard Fail Software Error Record’’ only under the following conditions:

if the Record Type Field (bytes 642-643) has a value of X’6501’,

the StorageTek identifier (X’FEEDFACE’ at bytes 644-647) is present, and

the character ‘H’ appears at the byte 113 location.

Appendix D. Logging ACS Robotics Motion 607

1st ed., 6/30/04 - 312579601

Page 637
Image 637