StorageTek 6 manual Actions Permitted During an Audit, How the AUDIt Utility Functions

Models: 6

1 718
Download 718 pages 10.93 Kb
Page 230
Image 230
Actions Permitted During an Audit

Audit

If the media value is unreadable by the LMU (recorded in the CDS), the HSC issues a warning message.

If the media value is unreadable by the LMU (not recorded in the CDS), the HSC issues a warning message.

In both of these cases (APPLY(NO) or APPLY(YES)), the audit continues.

Actions Permitted During an Audit

During execution, AUDIt permits any of the following actions to occur within any LSM in which an audit is being conducted:

mounts

dismounts to the same or another LSM (if the home location exists prior to the start of the audit)

ejects

pass-thru events.

No new cartridge cell allocations can occur during audit processing within those LSMs being audited, so cartridge enters and pass-thrus with MNTD Float(ON) are not allowed in ACSs or LSMs involved in the audit. In addition, scratch redistribution is not allowed in an ACS being audited.

How the AUDIt Utility Functions

Each LSM element to be audited is scanned, cell by cell, and compared with the volume and cell information for the corresponding entries in the library control data set. If the APPly(YES) parameter is specified, the control data set is corrected to reflect the current contents of the inspected cell. If duplicate volumes are found in either a previously audited cell in the LSM currently being audited or another LSM, the last volume scanned is physically ejected.

Volumes which are to be ejected are moved to the CAP identified in the invoking control statement or to the highest-priority, available CAP. The CAP is not allocated until the Audit utility requires it.

If, during the Audit operation, a CAP is required and the scope of the Audit is a row or column level Audit, the CAP remains allocated until the Audit completes. If the scope of the Audit is for multiple panels or larger (such as an LSM or ACS level Audit), the operator is given the opportunity to release the CAP or have it remain allocated for the duration of the Audit.

Note: The opportunity to release the CAP is presented only after each full panel audit completes. An audit consisting of only one panel is not presented with the choice to reserve or release the CAP. The same logic applies to the last panel of a multiple-panel audit.

200VM/HSC 6.0 System Programmer’s Guide

1st ed., 6/30/04 - 312579601

Page 230
Image 230