StorageTek 6 Invoking the Enter Cartridges Utility, JCL Requirements, SCRatch, Slsprint, Slsin

Models: 6

1 718
Download 718 pages 10.93 Kb
Page 280
Image 280
SCRatch

Enter Cartridges

00

For 4410 and 9310 LSMs, standard 21-cell CAP or the right-hand 40-cell enhanced CAP

For 9360 LSMs, the 20-cell WolfCreek CAP

For 9740 LSMs, fixed rack 14-cell or 10-cell removable magazine CAP

For SL8500 libraries, the CAP consists of 3, 13-cell removable magazines.

01

For 4410 and 9310 LSMs, left-hand 40-cell enhanced CAP

For 9360 LSMs, the 30-cell WolfCreek optional CAP

For SL8500 libraries, this is an optional CAP consisting of 3, 13-cell removable magazines.

02

priority CAP (PCAP) for a 4410 or 9310 LSM enhanced CAP or for a 9360 LSM CAP.

SCRatch

When SCRatch is specified, it causes volumes to be put into scratch status.

JCL Requirements

The following definitions apply to the Enter Cartridges utility JCL:

SLSPRINT

output messages from the utility.

SLSIN

input to the utility in the form of control statement card images.

Invoking the Enter Cartridges Utility

The easiest way to run utilities is to execute the ACS UTIL exec by entering the following command:

EXEC ACS UTIL ENTER

Execution of the statement results in the ACSUTIL SLKJCL file:

ACSUTIL SLKJCL File

/JOB

jobname SLUADMIN

/PARM

MIXED

/FILE

SLSPRINT DEV PRNT CLASS A

/FILE

SLSIN *

* ENTER CAP(capid)

250VM/HSC 6.0 System Programmer’s Guide

1st ed., 6/30/04 - 312579601

Page 280
Image 280
StorageTek 6 manual Invoking the Enter Cartridges Utility, JCL Requirements, SCRatch, Slsprint, Slsin, ACSUTIL SLKJCL File