LONGItud

TAPEREQ

This parameter is ignored for an existing data set if the media characteristics are determined by the volume.

If this parameter is not specified, a default is chosen based on the value of the

RECtech parameter. Table 5 shows default values used if MEDia is omitted.

Table 5. TAPEREQ MEDia Default Values

RECtech Entered:

MEDia Default:

 

 

18track

Standard

 

 

36track, 36Atrack, 36Btrack

LONGItud

 

 

36Ctrack

ZCART

 

 

LONGItud

LONGItud

 

 

DD3, HELical

DD3

 

 

STK1R, STK1R34, STK1R35,

STK1R

STK1RA, STK1RA34, STK1RA35,

 

STK1RB, STK1RB34, STK1RB35,

 

STK1RAB, STK1RAB4, STK1RAB5,

 

STK1RC, STK1RC34, STK1RC35

 

 

 

STK2P, STK2P34, STK2P35, STK2PA,

STK2P

STK2PA34, STK2PA35, STK2PB,

 

STK2PB34, STK2PB35

 

 

 

To avoid problems, StorageTek recommends that all TAPEREQ statements specify MEDia and RECtech consistently. Make sure to include either one or both parameters on each statement. If both media type and recording technique are omitted, all available devices are eligible for allocation.

Valid media types are:

LONGItud

indicates any Standard, ECART, or ZCART cartridge.

Standard

indicates a standard length, 3480 cartridge. It can be read on any longitudinal drives (4480, 4490, 9490, or 9490EE). Data can be written in 36-track mode on 4490, 9490, or 9490EE transports but cannot be read on an 18-track (4480) drive. Synonyms for this type of cartridge include:

CST

MEDIA1

STD

1

3480.

ECART

indicates a 3490E, extended capacity cartridge. It can be used only on a

36-track drive (4490, 9490, or 9490EE). Synonyms include:

126VM/HSC 6.0 System Programmer’s Guide

1st ed., 6/30/04 - 312579601

Page 156
Image 156
StorageTek 6 manual Tapereq, LONGItud, Standard, Ecart