StorageTek 6 manual use-limit, Volattr, STK1RC34

Models: 6

1 718
Download 718 pages 10.93 Kb
Page 182
Image 182
use-limit

VOLATTR

STK1RC34

indicates a 3490-image T9840C transport.

STK1RC35

indicates a 3590-image T9840C transport.

STK2P

indicates any T9940A transport.

STK2P34

indicates a 3490E-image T9940A transport.

STK2P35

indicates a 3590-image T9940A transport.

STK2PA

indicates a T9940A transport.

STK2PA34

indicates a 3490E-image T9940A transport.

STK2PA35

indicates a 3590-image T9940A transport.

STK2PB

indicates a T9940B transport.

STK2PB34

indicates a 3490E-image T9940B transport.

STK2PB35

indicates a 3590-image T9940B transport.

MAXclean

optionally, specifies a maximum cleaning cartridge usage for the VOLSER or range of VOLSERs (1 to 32767) associated with the SERial parameter. Do not specify values that exceed the manufacturer’s recommendation for usage. MAXclean applies to all types of cleaning cartridges.

If this parameter is specified, the VOLSER(s) indicated in the SERial parameter must begin with the cleaning cartridge prefix established in the LIBGEN.

use-limit

indicates the maximum number of times a cleaning cartridge can be used before it is ejected.

152VM/HSC 6.0 System Programmer’s Guide

1st ed., 6/30/04 - 312579601

Page 182
Image 182
StorageTek 6 manual use-limit, Volattr, STK1RC34