StorageTek 6 manual Other Methods of Controlling Scratch Subpools, SCRPOol, Example

Models: 6

1 718
Download 718 pages 10.93 Kb
Page 132
Image 132
Other Methods of Controlling Scratch Subpools

SCRPOol

Example

The following is an example of using the Scratch Subpool control statement.

SCRPO NAME(SITE1),RANGE(100000-200000,300000-400000),LABEL(SL)

SCRPO NAME(SITE2),RANGE(500000-540072),LABEL(NL),HOSTID(HSC1)

SCRPO NAME(SITE3),RANGE(540081-610094),LABEL(NSL)

SCRPO NAME(SITE4),RANGE(AP1000-AP1999),LABEL(SL),HOSTID(HSC1,HSC6)

Other Methods of Controlling Scratch Subpools

There are other ways to control scratch volumes and scratch subpools in the library. The following are additional methods that may be used:

Display SCRatch command

Display command with THReshld parameter

ENter command specified with SCRatch parameter

SCREdist utility with SUBpool and BALtol parameters

EJect command with SCRTCH SUBpool parameters

Mount command with SCRTCH SUBpool parameters

Warn command with SCRatch SUBpool and THREShold parameters

Tape management system (TMS) interface.

Refer to the HSC Operator’s Guide for more information.

102VM/HSC 6.0 System Programmer’s Guide

1st ed., 6/30/04 - 312579601