StorageTek 6 manual How Information is Logged, Byte #, Description of Field

Models: 6

1 718
Download 718 pages 10.93 Kb
Page 635
Image 635
How Information is Logged

How Information is Logged

The HSC periodically retrieves the statistics for robotics motions begun and temporary errors from the LMU. This information is logged to SYS1.LOGREC as software errors as shown in the Table 67. This record is a valid ‘‘Initiated and Temporary Error Motion Software Error Record’’ only under the following circumstances:

if the Record Type Field (bytes 642-643) has value X’6506’ and

the StorageTek identifier (X’FEEDFACE’ at bytes 644-647) is present.

Such a record is called an LLG6 record. Refer to Appendix C, “Record Formats” on page 497 to see the record layout for LLG6.

Table 67. Format for Total Motions and Temporary Error Counts

Initiated and Temporary Error Motion Software Error Record

BYTE #

Description of Field

 

 

00-31

Standard HSC LOGREC header

 

 

00-00

X’40’ indicates software detected error

 

 

01-01

X’80’ indicates VS2 or later release level

 

 

02-02

X’08’ indicates TIME macro was used

 

 

03-03

X’20’ indicates record contains an error ID

 

 

04-05

Reserved

 

 

06-06

Record count

 

 

07-07

Reserved

 

 

08-11

System date of error

 

 

12-15

System time of error

 

 

16-23

CPU ID

 

 

24-31

Subsystem name

 

 

32-35

Eyeball characters ‘LLG6’

 

 

36-41

Proprietary data

 

 

42-43

Reserved

 

 

44-44

ACSid (binary)

 

 

45-45

Reserved

 

 

Appendix D. Logging ACS Robotics Motion 605

1st ed., 6/30/04 - 312579601