CUSTOM RESPONS
BATTERY
Your tractor has a battery charging system which is suffi- cient for normal use., However, periodic charging of the battery with an automotive charger will extend its life.
•Keep battery and terminals clean° o Keep battery bolts tight.,
o Keep small vent holes openr
o Recharge at
TO CLEAN BATTERY AND TERMINALS
Corrosion and dirt on the battew and terminals can cause the battery to "leak" power,
o Remove terminal guar&
°Disconnect BLACK battery cable first then RED bat- tery cable and remove battery from tractor.,
•Rinse the battery with plain water and dry.
•Clean terminals and battery cable ends with wire brush until brighL
. Coat terminals with grease or petroleum jelly.
°Reinstall battery (See "CONNECT BATTERY" in the Assembly section of this manual).,
V-BELTS
Check
TRANSAXLE COOLING
Keep transaxle free from
ENGINE
NOTE: Although
improve starting in cold weather, these
32°F, Check your engine oil level more frequently to avoid possible engine damage from running low on oil,
Change the oil after the first two hours of operation and every 25 hours thereafter or at least once a year if the tractor is not used for 25 hours in one year,.
Check the crankcase oil level before starting the engine and after each eight (8) hours of operation,, Tighten oil fill cap/dipstick securely each time you check the oil level,.
TO CHANGE ENGINE OIL (See Figs, 11 and 12)
Determine temperature range expected before oil change,, All oil must meet API service classification SF or SG.
•Be sure tractor is on level surface,
•Oil will drain more freely when warm.
•Catch oil in a suitable container,,
•Remove oil fill cap/dipstick,. Be careful not to allow dirt to enter the engine when changing oil,,
°Remove drain plug,,
°After oil has drained completely, replace oil drain plug and tighten securely,
°Refill engine with oil through oii fill dipstick tube. Pour slowly. Do not overfill,, For approximate capacity see
"PRODUCT SPECIFICATIONS" on page 3 of this manual
°Use gauge on oil fill cap/dipstick for checking level. Be sure dipstick cap is tightened securely for accurate reading,, Keep oil at "FULL" line on dipstick.
OIL FILL
CAPIDIPSTICK
LUBRICATION
Only use high quality detergent oil rated with AP! service classification SF or SG_ Select the oil'sSAE viscosity grade according to your expected operating temperature,
SAE VISCOSITY GRADES..............
FIG. 12
i_F | _20 _ | 0 ° | 30" | 320 40" | 60 _ |
| 800 | 'i00 _ | |
40° | oo | _;o | 2o | .........., | ' ' | i | |||
3o | 40° | ||||||||
| TEM,P,gRATuRE'RANGEANTiciPATED | BEFORENEXTOILCHANGE |
|
|
FIG. 11
OIL DRAIN
PLUG
'17