PROBLEM

CAUSE

CORRECTION

 

 

 

Regulator will not shut

Damaged regulator.

Replace.

off air outlet.

 

 

 

 

 

Motor will not run.

Fuse blown, circuit

Check fuse box

 

breaker tripped.

for blown fuse and

 

 

replace as necessary.

 

 

Reset circuit breaker.

 

 

Do not use a fuse or

 

 

circuit breaker with

 

 

higher rating than

 

 

that specified for your

 

 

particular branch circuit.

 

 

Check for proper fuse.

 

 

You should use a time

 

 

delay fuse.

 

 

Check for low voltage

 

 

problem.

 

 

Check the extension

 

 

cord.

 

 

Disconnect the other

 

 

electrical appliances

 

 

from circuit or operate

 

 

the compressor on its

 

 

own branch circuit.

 

Extension cord is wrong

Check the extension

 

length or gauge.

cord.

 

Loose electrical

Check wiring

 

connections.

connection inside

 

 

terminal box.

 

Faulty motor.

Have checked by

 

 

a Trained Service

 

 

Technician.

 

Motor overload protec-

Refer to Motor

 

tion switch has tripped

Overload Protection

 

 

under Operation.

 

 

If motor overload

 

 

protection trips

 

 

frequently, contact

 

 

a Trained Service

 

 

Technician.