PROBLEM | CAUSE | CORRECTION |
|
|
|
Pressure reading on | It is normal for "some" | If there is an excessive |
the regulated pressure | pressure drop to occur. | amount of pressure drop |
gauge drops when an |
| when the accessory |
accessory is used. |
| is used, adjust the |
|
| regulator following |
|
| the instructions in |
|
| the Description of |
|
| Operation paragraph in |
|
| the Operation Section. |
|
| NOTE: Adjust the |
|
| regulated pressure under |
|
| flow conditions (while |
|
| accessory is being |
|
| used). |
Compressor is not sup- | Prolonged excessive use | Decrease amount of air |
plying enough air to | of air. | usage. |
operate accessories. | Compressor is not large | Check the accessory |
| ||
| enough for air require- | air requirement. If it is |
| ment. | higher than the SCFM |
|
| or pressure supplied |
|
| by your air compressor, |
|
| you need a larger |
|
| compressor. |
| Hole in hose. | Check and replace if |
|
| required. |
| Check valve restricted. | Remove and clean, or |
|
| replace. |
| Air leaks. | Tighten fittings. |
|
|
|
Regulator knob has con- | Damaged regulator. | Replace. |
tinuous air leak. |
|
|
|
|
|
N014212 | 18 - ENG |